On 6/13/2011 2:15 AM, Mike Seda wrote:
I forgot to mention that during my debugging, I did have
"Heartbeat Interval" set to 10 on the Client, Storage, and
Director resources. The same error still occurred... Very odd.
I have encountered similar situations with clients. Everything but
Bacula would appear to work over the network, but Bacula would fail.
In one case it was a bad switch, and 2 or 3 other times it was a bad
NIC in the client. My conclusion is that Bacula is very sensitive to
network problems, and since it is network heavy during a backup, it
tends to reveal network problems when nothing else does. If the
client has been working in the past, then suddenly began failing
jobs, then the problem is not likely the config. The procedure I now
go through to diagnose client problems is something like:
1) If a win32 client, then disable OS power management (can turn off
NIC's PHY inappropriately)
2) Swap connections with an existing, known working client (if
possible)
3) Replace Ethernet patch cable
4) Connect client to a different switch (if possible)
5) Replace client's NIC
6) Try different plenum cabling or bypass plenum cabling if possible
7) Physically move client and directly connect to the switch SD is
connected to
For me, this error has always thus far ended up being a hardware
problem.
|
------------------------------------------------------------------------------
EditLive Enterprise is the world's most technically advanced content
authoring tool. Experience the power of Track Changes, Inline Image
Editing and ensure content is compliant with Accessibility Checking.
http://p.sf.net/sfu/ephox-dev2dev _______________________________________________
Bacula-users mailing list
Bacula-users AT lists.sourceforge DOT net
https://lists.sourceforge.net/lists/listinfo/bacula-users
|
|
|