On Tue, Jun 22, 2010 at 5:55 PM, Jeremiah D. Jester
<jjest AT u.washington DOT edu> wrote:
> No results in Scratch pool. I've included a verbose dump, just in case.
>
> Thanks.
> JJ
>
> *update
> Update choice:
>     1: Volume parameters
>     2: Pool from resource
>     3: Slots from autochanger
>     4: Long term statistics
> Choose catalog item to update (1-4): 3
> The defined Storage resources are:
>     1: File
>     2: Tape
> Select Storage resource (1-2): 2
> Enter autochanger drive[0]:
> Connecting to Storage daemon Tape at bacula.microslu.washington.edu:9103 ...
> 3306 Issuing autochanger "slots" command.
> Device "ADIC_Scalar_24" has 23 slots.
> Connecting to Storage daemon Tape at bacula.microslu.washington.edu:9103 ...
> 3306 Issuing autochanger "list" command.
> Catalog record for Volume "KL0401" updated to reference slot 2.
> Catalog record for Volume "KL0307" updated to reference slot 1.
> Volume "KL0423" not found in catalog. Slot=3 InChanger set to zero.
> Volume "KL0412" not found in catalog. Slot=4 InChanger set to zero.
> Volume "KL0440" not found in catalog. Slot=5 InChanger set to zero.
> Volume "KL0443" not found in catalog. Slot=6 InChanger set to zero.
> Volume "KL0406" not found in catalog. Slot=7 InChanger set to zero.
> Volume "KL0444" not found in catalog. Slot=8 InChanger set to zero.
> Volume "KL0310" not found in catalog. Slot=9 InChanger set to zero.
> Volume "000091" not found in catalog. Slot=10 InChanger set to zero.
> Volume "000082" not found in catalog. Slot=11 InChanger set to zero.
> Volume "KL0445" not found in catalog. Slot=12 InChanger set to zero.
> Volume "KL0367" not found in catalog. Slot=13 InChanger set to zero.
> Volume "KL0385" not found in catalog. Slot=14 InChanger set to zero.
> Volume "KL0393" not found in catalog. Slot=15 InChanger set to zero.
> Volume "KL0429" not found in catalog. Slot=16 InChanger set to zero.
> Volume "KL0456" not found in catalog. Slot=17 InChanger set to zero.
> Volume "000112" not found in catalog. Slot=18 InChanger set to zero.
> Volume "000111" not found in catalog. Slot=19 InChanger set to zero.
> Volume "KL0330" not found in catalog. Slot=20 InChanger set to zero.

At that point you want to issue

label barcodes

and put all volumes in the Scratch Pool.

Bacula will automatically grab from the scratch pool when any pool
needs volumes of the same media type. If you do not want that behavior
you can put them in some other pool.

John

------------------------------------------------------------------------------
ThinkGeek and WIRED's GeekDad team up for the Ultimate 
GeekDad Father's Day Giveaway. ONE MASSIVE PRIZE to the 
lucky parental unit.  See the prize list and enter to win: 
http://p.sf.net/sfu/thinkgeek-promo
_______________________________________________
Bacula-users mailing list
Bacula-users AT lists.sourceforge DOT net
https://lists.sourceforge.net/lists/listinfo/bacula-users

<Prev in Thread] Current Thread [Next in Thread>