On Fri, Sep 05, 2008 at 02:37:53PM -0400, Jason Dixon wrote:
> On Fri, Sep 05, 2008 at 01:51:14PM -0400, John Drescher wrote:
> > On Fri, Sep 5, 2008 at 1:48 PM, Jason Dixon <jdixon AT omniti DOT com>
> > wrote:
> > > I'm currently at the colo facility migrating a Solaris 10 backup server
> > > from NBU 4.5 to Bacula 2.4.2. I've been using FileStorage for a few
> > > days, everything is running smoothly (since going to 32-bit).
> > >
> > > Anyways, I'm trying to get the mtx-changer script working and I seem to
> > > be having some difficulty. I've installed CSWmtx (blastwave) and have
> > > tried testing using the same autochanger device that tl8test (NBU) was
> > > using but I'm getting nothing but errors.
> > >
> > > -bash-3.00$ sudo /opt/csw/sbin/mtx -f /dev/sg/c1t0l0 status
> > > mtx: Request Sense: Long Report=yes
> > > mtx: Request Sense: Valid Residual=no
> > > mtx: Request Sense: Error Code=0 (Unknown?!)
> > > mtx: Request Sense: Sense Key=No Sense
> > > mtx: Request Sense: FileMark=no
> > > mtx: Request Sense: EOM=no
> > > mtx: Request Sense: ILI=no
> > > mtx: Request Sense: Additional Sense Code = 00
> > > mtx: Request Sense: Additional Sense Qualifier = 00
> > > mtx: Request Sense: BPV=no
> > > mtx: Request Sense: Error in CDB=no
> > > mtx: Request Sense: SKSV=no
> > > INQUIRY command Failed
> > >
> > > Any suggestions?
> > >
> > Was the changer doing an inventory when you ran mtx? Is bacula-sd running?
>
> It shouldn't have been. Yes, bacula-sd is running but no scheduled jobs
> are enabled to use this unit yet (only FileStorage). I started by
> trying to "label barcodes" and it reported no slots:
>
> *label barcodes
> Automatically selected Catalog: MyCatalog
> Using Catalog "MyCatalog"
> The defined Storage resources are:
> 1: Sony SDX-700C
> 2: FileStorage
> Select Storage resource (1-2): 1
> Connecting to Storage daemon Sony SDX-700C at backup-va-1:9103 ...
> 3306 Issuing autochanger "slots" command.
> Device "Sony SDX-700C" has 0 slots.
> No slots in changer to scan.
> You have messages.
>
> Then I started looking at the changer/mtx controls to diagnose it. Here
> are my Autochanger and Device sections, in case I've messed something
> up. I haven't made any changes to the mtx-changer script yet.
>
> Autochanger {
> Name = "QUALSTAR TLS-4212i"
> Device = "Sony SDX-700C"
> Changer Command = "/opt/bacula/libexec/mtx-changer %c %o %S %a %d"
> Changer Device = /dev/sg/c1t0l0
> }
>
> Device {
> Name = "Sony SDX-700C"
> Media Type = AIT-3
> Archive Device = /dev/rmt/0cbn
> AutomaticMount = yes;
> AlwaysOpen = yes;
> RemovableMedia = yes;
> RandomAccess = no;
> AutoChanger = yes
> # Enable the Alert command only if you have the mtx package loaded
> Alert Command = "sh -c 'tapeinfo -f %c |grep TapeAlert|cat'"
> }
I just noticed the following lines in /var/adm/messages. I'm going to
look at the library and see if I can issue an inventory from there. If
that doesn't work, I'll reboot the server and library.
Sep 5 13:11:59 backup-va-1 scsi: [ID 107833 kern.warning] WARNING:
/pci@1c,60000 0/scsi@2,1/st@1,0 (st8):
Sep 5 13:11:59 backup-va-1 Error for Command: rezero/rewind
Error Level: Fatal
Sep 5 13:11:59 backup-va-1 scsi: [ID 107833 kern.notice]
Requested Block: 0 Error Block: 0
Sep 5 13:11:59 backup-va-1 scsi: [ID 107833 kern.notice] Vendor:
SONY Serial Number:
Sep 5 13:11:59 backup-va-1 scsi: [ID 107833 kern.notice] Sense
Key: Not Re ady
Sep 5 13:11:59 backup-va-1 scsi: [ID 107833 kern.notice] ASC:
0x3a (medium not present), ASCQ: 0x0, FRU: 0x0
Thanks,
--
Jason Dixon
OmniTI Computer Consulting, Inc.
jdixon AT omniti DOT com
443.325.1357 x.241
-------------------------------------------------------------------------
This SF.Net email is sponsored by the Moblin Your Move Developer's challenge
Build the coolest Linux based applications with Moblin SDK & win great prizes
Grand prize is a trip for two to an Open Source event anywhere in the world
http://moblin-contest.org/redirect.php?banner_id=100&url=/
_______________________________________________
Bacula-users mailing list
Bacula-users AT lists.sourceforge DOT net
https://lists.sourceforge.net/lists/listinfo/bacula-users
|