Re: [Veritas-bu] bpcd 13782 - drops connection from master server
2011-09-16 13:29:05
Are you removing the old master from bp.conf on the clients and putting in the
new master?
Are you upgrading NBU on the clients to match version on the new master? Are
any of these clients media servers?
-----Original Message-----
From: veritas-bu-bounces AT mailman.eng.auburn DOT edu
[mailto:veritas-bu-bounces AT mailman.eng.auburn DOT edu] On Behalf Of Marianne
Van Den Berg
Sent: Friday, September 16, 2011 1:08 PM
To: 'veritas-bu AT mailman.eng.auburn DOT edu'
Subject: Re: [Veritas-bu] bpcd 13782 - drops connection from master server
Which NBU version? Since 6.0 server/client connection use vnetd (13724) only.
M.
Sent from my BlackBerry Bold
----- Original Message -----
From: brettkan [mailto:nbu-forum AT backupcentral DOT com]
Sent: Friday, September 16, 2011 06:41 PM
To: VERITAS-BU AT MAILMAN.ENG.AUBURN DOT EDU <VERITAS-BU AT MAILMAN.ENG.AUBURN
DOT EDU>
Subject: [Veritas-bu] bpcd 13782 - drops connection from master server
The issue - when master server initiates a session to client on port 13782, it
drops immediately. Thus, bkps are not running. We are migrating clients off
an old NetBackup server to this new server.
Tests done:
1-client can telnet to master server on ports 13782 (and maintains connection)
2-master server can still connect to port 13782 on other clients (80+ clients
are working without issue)
3-master server can telnet to other NetBackup service port 13724 on client (and
maintains connection)
4-old NetBackup master server can telnet to ports 13724, 13782 on client (and
maintains connection)
Steps taken:
1-restarted NetBackup services on client
2-no firewalls or ACLs exist between client and master server.
3-reinstalled the NetBackup client
4-verified routes, bp.conf, services started
Has anyone ever deal with something like this before? Looking for any ideas.
Network team, server groups and Symantec not sure of issue.
Thanks,
Brett
+----------------------------------------------------------------------
|This was sent by brett.t.kandolf AT fisglobal DOT com via Backup Central.
|Forward SPAM to abuse AT backupcentral DOT com.
+----------------------------------------------------------------------
_______________________________________________
Veritas-bu maillist - Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
_______________________________________________
Veritas-bu maillist - Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
Proud partner. Susan G. Komen for the Cure.
Please consider our environment before printing this e-mail or attachments.
----------------------------------
CONFIDENTIALITY NOTICE: This e-mail may contain privileged or confidential
information and is for the sole use of the intended recipient(s). If you are
not the intended recipient, any disclosure, copying, distribution, or use of
the contents of this information is prohibited and may be unlawful. If you have
received this electronic transmission in error, please reply immediately to the
sender that you have received the message in error, and delete it. Thank you.
----------------------------------
_______________________________________________
Veritas-bu maillist - Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
|
<Prev in Thread] |
Current Thread |
[Next in Thread>
|
- [Veritas-bu] bpcd 13782 - drops connection from master server, brettkan
- Re: [Veritas-bu] bpcd 13782 - drops connection from master server, Marianne Van Den Berg
- Re: [Veritas-bu] bpcd 13782 - drops connection from master server,
Lightner, Jeff <=
- [Veritas-bu] bpcd 13782 - drops connection from master server, brettkan
- Re: [Veritas-bu] bpcd 13782 - drops connection from master server, Patrick
- [Veritas-bu] bpcd 13782 - drops connection from master server, brettkan
- [Veritas-bu] bpcd 13782 - drops connection from master server, brettkan
- Re: [Veritas-bu] bpcd 13782 - drops connection from master server, Reynolds, Susan K.
- [Veritas-bu] bpcd 13782 - drops connection from master server, brettkan
|
|
|