Re: [Bacula-users] Is tape filling up too early?
2012-10-18 09:10:41
I did on the tape that is full
2012/10/18, John Drescher <drescherjm AT gmail DOT com>:
>> These are my results:
>>
>> smartctl version 5.36 [x86_64-redhat-linux-gnu] Copyright (C) 2002-6 Bruce
>> Allen
>> Home page is http://smartmontools.sourceforge.net/
>>
>> Device: IBM HH LTO Gen 3 Version: 76B0
>> Serial number: 1020024392
>> Device type: tape
>> Transport protocol: SAS
>> Local Time is: Thu Oct 18 09:34:18 2012 ART
>> Temperature Warning Disabled or Not Supported
>> TapeAlert Supported
>> TapeAlert: OK
>>
>> Error counter log:
>> Errors Corrected by Total Correction
>> Gigabytes Total
>> ECC rereadDataCompEnableds/ errors
>> algorithm processed uncorrected
>> fast | delayed rewrites corrected invocations [10^9
>> bytes] errors
>> read: 0 0 0 0 0
>> 0.000 0
>> write: 0 0 0 0 0
>> 0.000 0
>>
>> Non-medium error count: 0
>> Device does not support Self Test logging
>
> Although I have only tried this command 1 time, I think you need to do
> that after using the drive for a while or filling a tape. Since there
> is no result..
>
>> [root@superback ~]# mt -f /dev/nst0 compression 1
>
> Was there any data on the tape when you executed this command.
> Remember you can not turn on compression if anything is written to the
> tape. You must erase it first.
>
> mt -f /dev/nst0 rewind
> mt -f /dev/nst0 weof
>
> John
>
--
Enviado desde mi dispositivo móvil
--
Sergio Belkin http://www.sergiobelkin.com
Watch More TV http://sebelk.blogspot.com
LPIC-2 Certified - http://www.lpi.org
------------------------------------------------------------------------------
Everyone hates slow websites. So do we.
Make your web apps faster with AppDynamics
Download AppDynamics Lite for free today:
http://p.sf.net/sfu/appdyn_sfd2d_oct
_______________________________________________
Bacula-users mailing list
Bacula-users AT lists.sourceforge DOT net
https://lists.sourceforge.net/lists/listinfo/bacula-users
|
|
|