On Thu, 19 Jul 2012, Dan Langille wrote:

> On 2012-07-15 13:48, Steve Thompson wrote:
>> On Sun, 15 Jul 2012, Thomas Lohman wrote:
>> 
>>> This actually is a hardcoded "sanity" check in the code itself.  Search
>>> the mailing lists from the past year.  I'm pretty sure I posted where in
>>> the code this was and what needed to be changed.
>> 
>> Excellent; thank you! I have found your post and the relevant code.
>
> Please let us know how that went.

The long backup finally completed; I was expecting a run time of 14 days,
but it actually took 12 days and 2 hours. In bacula 5.0.2, the code to
be modified is at line 687 of lib/bnet.c, and line 76 of lib/bsock.c; the
modifications are obvious.

Steve

------------------------------------------------------------------------------