Hello,

2012/6/26 Jens Gruentjes <jens.gruentjes AT ebira DOT de>
boromir ~/tdtool # mtx -f /dev/sg4 status
RequestSense (0x03) failed
mtx: Request Sense: Long Report=yes
mtx: Request Sense: Valid Residual=no
mtx: Request Sense: Error Code=70 (Current)
mtx: Request Sense: Sense Key=Unit Attention
mtx: Request Sense: FileMark=no
mtx: Request Sense: EOM=no
mtx: Request Sense: ILI=no
mtx: Request Sense: Additional Sense Code = 28
mtx: Request Sense: Additional Sense Qualifier = 00
mtx: Request Sense: BPV=no
mtx: Request Sense: Error in CDB=no
mtx: Request Sense: SKSV=no
Mode sense (0x1A) for Page 0x1D failed
  Storage Changer /dev/sg4:1 Drives, 8 Slots ( 0 Import/Export )
Data Transfer Element 0:Full (Storage Element 3 Loaded):VolumeTag = WOC4-03L4
      Storage Element 1:Full :VolumeTag=WOC4-01L4
      Storage Element 2:Full :VolumeTag=WOC4-02L4
      Storage Element 3:Empty
      Storage Element 4:Full :VolumeTag=WOC5-01L4
      Storage Element 5:Full :VolumeTag=WOC5-02L4
      Storage Element 6:Full :VolumeTag=WOC5-03L4
      Storage Element 7:Full :VolumeTag=WOC1-01L4
      Storage Element 8:Full :VolumeTag=WOC1-02L4


Check this out! 8 slots reported :)


boromir ~/tdtool # mtx -f /dev/sg4 status
  Storage Changer /dev/sg4:1 Drives, 7 Slots ( 0 Import/Export )
Data Transfer Element 0:Full (Storage Element 3 Loaded):VolumeTag = WOC4-03L4
      Storage Element 1:Full :VolumeTag=WOC4-01L4
      Storage Element 2:Full :VolumeTag=WOC4-02L4
      Storage Element 3:Empty
      Storage Element 4:Full :VolumeTag=WOC5-01L4
      Storage Element 5:Full :VolumeTag=WOC5-02L4
      Storage Element 6:Full :VolumeTag=WOC5-03L4
      Storage Element 7:Full :VolumeTag=WOC1-01L4


Wow, 7 slots again. Do you delete a last line? :) Just kidding.
 
The two commands were issued directly one after another because I
worried about the first responses of the changer (RequestSense (0x03)
failed ...).


Please, hard reset your changer (off/on), check all connections, check all firmware options which could disable one slot - cleaning slot, etc. Then check library status with mtx again. It should work. If not, check you HBA firmware and OS driver.

best regards

--
Radosław Korzeniewski
radoslaw AT korzeniewski DOT net
------------------------------------------------------------------------------
Live Security Virtual Conference
Exclusive live event will cover all the ways today's security and 
threat landscape has changed and how IT managers can respond. Discussions 
will include endpoint security, mobile security and the latest in malware 
threats. http://www.accelacomm.com/jaw/sfrnl04242012/114/50122263/
_______________________________________________
Bacula-users mailing list
Bacula-users AT lists.sourceforge DOT net
https://lists.sourceforge.net/lists/listinfo/bacula-users
<Prev in Thread] Current Thread [Next in Thread>