On Wed, 16 Jun 2010, Michael Siroskey wrote:

> I am currently trying to get an autochanger working in 5.0.2.  The
> autochanger was working in 3.x but sense then we had to replace the
> server the storage daemon runs on, changed the host name and updated
> Bacula to the latest version.  The autochanger is running on a
> difference system then the director.   When I issue an update slots scan
> from bconsole I receive "No slots in changer to scan" but when I run
> mtx-changer script directly on the storage daemon host and get the
> correct response of 48 slots.  Any ideas?

File ownership/permissions of mtx and/or the /dev/sg* devices




------------------------------------------------------------------------------