Re: [Bacula-users] HP msl5030 misfunctions ...
2009-03-04 08:42:19
On Wed, Mar 4, 2009 at 3:29 AM, mimmo lariccia <mum_laris AT hotmail DOT com>
wrote:
> Hi Michael and thanks for fast answer...
> Hi all....
>
> I hope you're right.
> But these are results of my tests:
>
> # lsscsi
> [0:0:0:0] mediumx COMPAQ MSL5000 Series 0423 -
> [0:0:0:1] tape HP Ultrium 1-SCSI E38W /dev/st0
> [0:0:0:2] storage HP NS E1200-160 530b -
>
> # mtx -f /dev/sg0 status
> Storage Changer /dev/sg0:2 Drives, 30 Slots ( 1 Import/Export )
Use the tapeinfo command instead
tapeinfo -f /dev/sg0
This works on any sg device
# tapeinfo -f /dev/sg0
Product Type: CD-ROM
Vendor ID: 'LITE-ON '
Product ID: 'DVDRW LDW-851S '
Revision: 'GS0C'
Attached Changer: No
SCSI ID: 0
SCSI LUN: 0
Ready: no
# tapeinfo -f /dev/sg1
Product Type: Disk Drive
Vendor ID: 'ATA '
Product ID: 'ST3750330AS '
Revision: 'SD04'
Attached Changer: No
SerialNumber: ' 3QK02QVL'
SCSI ID: 0
SCSI LUN: 0
Ready: yes
I don't have a tape drive connected here at home so I can not show you
tape or changer results but I know this works at work.
John
------------------------------------------------------------------------------