Bacula-users

Re: [Bacula-users] Adding volumes to a certain Pool

2009-02-13 11:34:02
Subject: Re: [Bacula-users] Adding volumes to a certain Pool
From: Win Htin <win.htin AT gmail DOT com>
To: Brian Debelius <bdebelius AT intelesyscorp DOT com>
Date: Fri, 13 Feb 2009 11:31:02 -0500
Thanks Brian. Problem fixed.

On Fri, Feb 13, 2009 at 10:36 AM, Brian Debelius
<bdebelius AT intelesyscorp DOT com> wrote:
> Hi,
>
> This was just discussed here:
> http://article.gmane.org/gmane.comp.sysutils.backup.bacula.general/51284
>
>
> Win Htin wrote:
>>
>> Hi folks,
>>
>> How do I put Volumes into a particular Pool? I'm running version 2.4.4 on
>> RHEL5.
>>
>> Currently, from "bconsole" when I run "update slots" I see:
>>
>> *update slots
>> The defined Storage resources are:
>>     1: File
>>     2: TS3100_1
>> Select Storage resource (1-2): 2
>> Connecting to Storage daemon TS3100_1 at baculatest:9103 ...
>> 3306 Issuing autochanger "slots" command.
>> Device "LTO4_1" has 23 slots.
>> Connecting to Storage daemon TS3100_1 at baculatest:9103 ...
>> 3306 Issuing autochanger "list" command.
>> Catalog record for Volume "100ADU" updated to reference slot 1.
>> Catalog record for Volume "101ADU" updated to reference slot 2.
>> Volume "103ADU" not found in catalog. Slot=4 InChanger set to zero.
>> Volume "104ADU" not found in catalog. Slot=5 InChanger set to zero.
>> Volume "102ADU" not found in catalog. Slot=3 InChanger set to zero.
>>
>> I would like to add the Volumes 102ADU ~ 104ADU to the Scratch pool.
>> When I ran the following, I got an error message saying the Volume is
>> already labeled.
>>
>> *label barcodes Storage=TS3100_1 Pool=Scratch Slots=3
>> Connecting to Storage daemon TS3100_1 at baculatest:9103 ...
>> 3306 Issuing autochanger "slots" command.
>> Device "LTO4_1" has 23 slots.
>> Connecting to Storage daemon TS3100_1 at baculatest:9103 ...
>> 3306 Issuing autochanger "list" command.
>> The following Volumes will be labeled:
>> Slot  Volume
>> ==============
>>   3  102ADU
>> Do you want to label these Volumes? (yes|no): yes
>> Connecting to Storage daemon TS3100_1 at baculatest:9103 ...
>> Sending label command for Volume "102ADU" Slot 3 ...
>> 3307 Issuing autochanger "unload slot 5, drive 0" command.
>> 3304 Issuing autochanger "load slot 3, drive 0" command.
>> 3305 Autochanger "load slot 3, drive 0", status is OK.
>> 3920 Cannot label Volume because it is already labeled: "102ADU"
>> Label command failed for Volume 102ADU.
>>
>> Thanks in advance.
>>
>> Win
>>
>>
>> ------------------------------------------------------------------------------
>> Open Source Business Conference (OSBC), March 24-25, 2009, San Francisco,
>> CA
>> -OSBC tackles the biggest issue in open source: Open Sourcing the
>> Enterprise
>> -Strategies to boost innovation and cut costs with open source
>> participation
>> -Receive a $600 discount off the registration fee with the source code:
>> SFAD
>> http://p.sf.net/sfu/XcvMzF8H
>> _______________________________________________
>> Bacula-users mailing list
>> Bacula-users AT lists.sourceforge DOT net
>> https://lists.sourceforge.net/lists/listinfo/bacula-users
>>
>
>



-- 
email : win.htin AT gmail DOT com
"The unexamined life is not worth living" -- Socrates

------------------------------------------------------------------------------
Open Source Business Conference (OSBC), March 24-25, 2009, San Francisco, CA
-OSBC tackles the biggest issue in open source: Open Sourcing the Enterprise
-Strategies to boost innovation and cut costs with open source participation
-Receive a $600 discount off the registration fee with the source code: SFAD
http://p.sf.net/sfu/XcvMzF8H
_______________________________________________
Bacula-users mailing list
Bacula-users AT lists.sourceforge DOT net
https://lists.sourceforge.net/lists/listinfo/bacula-users