> Dear Bob
>
> I saw this problem when I reported a major bug with 2.4.0 I recommend
> you go back to 2.2.8 until Kern and others release a fix.
>
> Kern could not repeat the error you and I seem to see. The system seems
> to be comparing the tape in the catalog and the tape in the unit.
>
> The tapes are physically OK but the data is being overwritten on the
> tape in the unit.
>
> Kern issued a warning regarding the problem - it seems to occur with
> those changing the tapes manually.
>
> Regards
> Stephen Carr
I'm using an autochanger. Anybody else using an autochanger seeing this
issue? Guess we should identify whether it's the same bug or a different
one too.
-------------------------------------------------------------------------