=> > Obviously, the changer is sending back a string with more stuff in it
=> > than just the barcode.
I missed the beginning of this thread, but be aware that the issue may be
configurable on the changer. For example, on the Dell PV132T (a re-badged ADIC
changer), there are 3 levels of output possible:
* Default: The scanner will expect to read and will report to the host six
characters. Optional one or two character media identifiers can be present but
will not be reported.
* Media ID: The scanner will expect to read and will report to the host seven
or eight characters (six plus the media identifier).
* Extended: The scanner will read and report to the host between five and
sixteen characters
=> >
=> > I can load each tape into the drive manually and label them with the
=> > correct barcode names, but it would be real nice to have the command do
=> > the job automatically as I perceive it was intended. Suggestions?
=> >
=> You definitely do not want to do that because it will leave you with
=> an autochanger without the barcode functionality.You probably need to
=> edit the mtx-changer script to get bacula to understand your mtx
=> output.
I suggest that the "Right Way" to deal with this would be to extend the
mtx-changer script to allow reference to an external file that defines the
expected barcode scanner output format. The default would correspond to the
current format that's hard-coded into the mtx-changer script.
Mark "making suggestions, but without the time to donate an implementation"
Bergman
=>
=> John
=>
=>
=>
=> --
=> John M. Drescher
=>
----
Mark Bergman voice: 215-662-7310
mark.bergman AT uphs.upenn DOT edu fax: 215-614-0266
System Administrator Section of Biomedical Image Analysis
Department of Radiology University of Pennsylvania
PGP Key: https://www.rad.upenn.edu/sbia/bergman
The information contained in this e-mail message is intended only for the
personal and confidential use of the recipient(s) named above. If the reader of
this message is not the intended recipient or an agent responsible for
delivering it to the intended recipient, you are hereby notified that you have
received this document in error and that any review, dissemination,
distribution, or copying of this message is strictly prohibited. If you have
received this communication in error, please notify us immediately by e-mail,
and delete the original message.
-------------------------------------------------------------------------
Check out the new SourceForge.net Marketplace.
It's the best place to buy or sell services for
just about anything Open Source.
http://sourceforge.net/services/buy/index.php
_______________________________________________
Bacula-users mailing list
Bacula-users AT lists.sourceforge DOT net
https://lists.sourceforge.net/lists/listinfo/bacula-users
|