Re: Amanda 2.6.0 spanning
2008-06-19 12:00:26
Johan,
Your problem is here:
On Wednesday 18 June 2008 11:15:32 Johan Booysen wrote:
> chg-manual contains:
>
> firstslot=1
> lastslot=1
You'll need to have more than one "slot" if you want to use multiple tapes.
Just increase 'lastslot' to 2 (or even to the total number of tapes you
possess), and Amanda will dutifully send you an e-mail asking for the next
tape.
Cheers,
--Ian
--