Re: Issue with tape changer configuration
2003-12-29 10:09:41
On Tue, 23 Dec 2003 at 1:57pm, Henson, George Mr JMLFDC wrote
> We new to Amanda and are having an issue getting the bar code reader to work
> in our tape changer. We have an HP C7200 (2 LTO drives/20 media slots)
> connected to an N class HP Server (HP/UX 11i amanda-2.4.4).
>
> The HP supplied utils (ltt tools) are able to read the barcode info from the
> tape silo, move the tapes, and inventory the robot with no known issues.
>
> I have tried to configure the chg-scsi interface with marginal success. If I
> turn off the barcode reader (havebarcode 0) then I can get Amanda to run
> backups and amtape seems to act normal. If I understand correctly, this also
> means the system must do a linear search for the media in the silo, instead
> of using the barcode info.
Have you tried mtx? See how well it controls your library, and then see
how configuring it goes.
And please throw some linebreaks into your messages...
--
Joshua Baker-LePain
Department of Biomedical Engineering