On Thu, Jul 08, 2010 at 04:24:59PM -0400, Brandon35 wrote:
> 
> Im having tape drives show up with the same BUS address...
> 
> Drive 1 Location: Bus Number 0, Target ID 1, LUN 0
> Drive 2 Location: Bus Number 0, Target ID 2, LUN 0
> Drive 3 Location: Bus Number 0, Target ID 3, LUN 0
> Drive 4 Location: Bus Number 0, Target ID 4, LUN 0
> Drive 5 Location: Bus Number 0, Target ID 5, LUN 0
> Drive 6 Location: Bus Number 0, Target ID 1, LUN 0
> Drive 7 Location: Bus Number 0, Target ID 2, LUN 0
> Drive 8 Location: Bus Number 0, Target ID 3, LUN 0
> Drive 9 Location: Bus Number 0, Target ID 4, LUN 0

I believe that the specific HBA is not shown here.  Every drive needs to
have a unique PORT/BUS/TARGET/LUN combo, but you're not seeing the first
bit.

If you look at 'scan -tape' output, you should see it:

media6$ scan -tape | grep ^Port
Port: 3; Bus: 0; Target: 4; LUN: 1
Port: 3; Bus: 0; Target: 4; LUN: 2
Port: 3; Bus: 0; Target: 4; LUN: 3
Port: 3; Bus: 0; Target: 4; LUN: 4
Port: 3; Bus: 0; Target: 4; LUN: 5
Port: 3; Bus: 0; Target: 4; LUN: 6
Port: 3; Bus: 0; Target: 5; LUN: 1
Port: 3; Bus: 0; Target: 5; LUN: 2
Port: 3; Bus: 0; Target: 5; LUN: 3
Port: 3; Bus: 0; Target: 5; LUN: 4
Port: 3; Bus: 0; Target: 5; LUN: 5
Port: 3; Bus: 0; Target: 5; LUN: 6
Port: 5; Bus: 0; Target: 4; LUN: 0
Port: 5; Bus: 0; Target: 4; LUN: 1
Port: 5; Bus: 0; Target: 4; LUN: 2
[...]

-- 