[Networker] HP LTO3 Drives with Linux RHEL4 Storagenode
2008-10-20 05:15:02
NeilD wrote:
> Have you checked CDI is switched off in Neworker for the drives?
>
>
> via RSS at http://listserv.temple.edu/cgi-bin/wa?RSS&L=NETWORKER
Thank you, NeilD, for CDI
I have disabled it . And it seems like one drive works properly.
But there is another question...
Now i have following
[email protected]:HP Ultrium 3-SCSI M63S|Tape, /dev/sg0
S/N: HU10810A9F
ATPN:HP Ultrium 3-SCSI
HU10810A9F
WWNN:50060B0000630122
WWPN:50060B0000630120
PORT:00000001
[email protected]:HP Ultrium 3-SCSI M63S|Tape, /dev/nst1
S/N: HU1080639T
ATPN:HP Ultrium 3-SCSI
HU1080639T
WWNN:50060B00006301AE
WWPN:50060B00006301AC
PORT:00000001
Second one - /dev/nst1 works fine.
But /dev/sg0 doesn't work.
What should i do to determine drive path(link) for the system ?
There should be some conf file as i guess...
+----------------------------------------------------------------------
|This was sent by vkaj AT tengizchevroil DOT com via Backup Central.
|Forward SPAM to abuse AT backupcentral DOT com.
+----------------------------------------------------------------------
To sign off this list, send email to listserv AT listserv.temple DOT edu and
type "signoff networker" in the body of the email. Please write to
networker-request AT listserv.temple DOT edu if you have any problems with this
list. You can access the archives at
http://listserv.temple.edu/archives/networker.html or
via RSS at http://listserv.temple.edu/cgi-bin/wa?RSS&L=NETWORKER
|
|
|