Veritas-bu

Re: [Veritas-bu] Converting standard client to a media server

2013-08-15 17:46:59
Subject: Re: [Veritas-bu] Converting standard client to a media server
From: Rusty Major <rusty.major AT sungard DOT com>
To: VERITAS-BU AT mailman.eng.auburn DOT edu
Date: Thu, 15 Aug 2013 16:46:38 -0500
Hey Dennis,

Did you change the IP or hostname?
clear host cache (bpclntcmd -clear_host_cache) on all boxes?
Restart PBX on master?
Can you run nbemmcmd -listhosts from the new media server?
Did you manually add the new media server to the master: ./nbemmcmd -addhost -machinename <newmedianame> -machinetype -media -masterserver <mastername> -operatingsystem <os type> -netbackupversion <version>

I think that's what the command is.

I'm sure you've done all that, but thought I would throw it out there.

On Thu, Aug 15, 2013 at 4:25 PM, Dennis Peacock <nbu-forum AT backupcentral DOT com> wrote:
Netbackup 7.5.0.5
Both boxes are RedHat Linux Release 6
Box "A" is the master and has always been the master/media server.
Box "B" has always been a standard client backing up across the network.

Licensing purchased and Box "B" was cleanly installed as a media server.

The master server can't see Box "B" as a media server.
bp.conf file checked and tweaked on both boxes.
Netbackup has been stopped and restarted several times.

Tried to manually add it to the master and I get this message:
globalDB hostname has not been set (Status 4)

4 of us have tried to get this working.....all have failed so far.

Tips, pointers, tricks, advice......all would be appreciated.

+----------------------------------------------------------------------
|This was sent by dpeaco AT acxiom DOT com via Backup Central.
|Forward SPAM to abuse AT backupcentral DOT com.
+----------------------------------------------------------------------


_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu




--
Rusty Major ▪ Technical Architect and Team Lead - Backup Infrastructure Engineering ▪ Sungard Availability Services ▪ 757 N. Eldridge Pkwy., Suite 200, Houston, TX 77079 ▪ 281-584-4693 ▪ Cell 713-724-4914 ▪ rusty.major AT sungard DOT com
------------------------------------------------------------------------------
Think before you Print 
CONFIDENTIALITY:  This e-mail (including any attachments) may contain confidential, proprietary and privileged information, and unauthorized disclosure or use is prohibited.  If you received this e-mail in error, please notify the sender and delete this e-mail from your system.
_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu