Thanks Patti,
first, planning to relocate the tape in the import/export slot... not sure why
i did not notice that..too occupied with the rest i guess..thanks for the HU!
so the labels were created on a completely separate bacula installation so the
labels are not in thie catalog on this machine... and no the labels were not
removed previously. i was hoping that bacula might take care of that for me,
but alas, no. i found a procedure to remove the labels via mtx-changer and did
that for each of the slots needed. then issued the label barcode via bconsole
and that seemed to work like a charm. This morning it looks like almost all
the new tapes are showing...on missing is currently in the import/export slot
and i plan on moving that this AM.
+----------------------------------------------------------------------