On Jul 7, 2011, at 2:13 PM, Martin Simmons wrote:
>>>>>> On Thu, 7 Jul 2011 10:30:36 -0600, James Woodward said:
>>
>> Hello,
>>
>> I haven't seen anything about using nsa devices to use over something like
>> an sa device. I did a bit of a search but haven't seen anything that really
>> explains that portion to me.
>
> http://www.bacula.org/5.0.x-manuals/en/main/main/Storage_Daemon_Configuratio.html#SECTION002030000000000000000
> http://www.bacula.org/5.0.x-manuals/en/problems/problems/Testing_Your_Tape_Drive.html#SECTION00413000000000000000
>
> Also, all of the examples use non-rewind devices.
>
>
>> When I set these up I did see a recommendation to use the pass through
>> devices e.g pass0, pass1, pass2, pass3. I don't remember the specifics but
>> the passthrough devices themselves seemed to be problematic.
>
> Yes, the passthrough devices shouldn't be used for data transfer. They should
> be used to control an autochanger robot.
Normally, under FreeBSD, you will have a ch device for your autoloader, which
you should use instead. E.g.,
tape# camcontrol devlist
<QUANTUM ULTRIUM 4 2210> at scbus0 target 8 lun 0 (sa0,pass0)
<QUANTUM UHDL 0075> at scbus0 target 8 lun 1 (ch0,pass1)
[[...]]
The chio command uses /dev/ch0 by default.
Cheers,
Paul.
------------------------------------------------------------------------------
All of the data generated in your IT infrastructure is seriously valuable.
Why? It contains a definitive record of application performance, security
threats, fraudulent activity, and more. Splunk takes this data and makes
sense of it. IT sense. And common sense.
http://p.sf.net/sfu/splunk-d2d-c2
_______________________________________________
Bacula-users mailing list
Bacula-users AT lists.sourceforge DOT net
https://lists.sourceforge.net/lists/listinfo/bacula-users
|