Bacula-users

Re: [Bacula-users] I/O error during label

2008-09-12 16:27:59
Subject: Re: [Bacula-users] I/O error during label
From: "John Drescher" <drescherjm AT gmail DOT com>
To: "Jason Dixon" <jdixon AT omniti DOT com>, bacula-users <Bacula-users AT lists.sourceforge DOT net>
Date: Fri, 12 Sep 2008 16:27:54 -0400
On Fri, Sep 12, 2008 at 4:22 PM, Jason Dixon <jdixon AT omniti DOT com> wrote:
> I see this I/O error after every label attempt.  Everything seems to be
> fine, but I just want to know if this is expected behavior or anything
> to watch out for.
>
> Connecting to Storage daemon Sony SDX-700C at backup-va-1:9103 ...
> Sending label command for Volume "000074" Slot 4 ...
> 3307 Issuing autochanger "unload slot 3, drive 0" command.
> 3304 Issuing autochanger "load slot 4, drive 0" command.
> 3305 Autochanger "load slot 4, drive 0", status is OK.
> block.c:999 Read error on fd=6 at file:blk 0:0 on device "Sony SDX-700C"
> (/dev/rmt/0cn). ERR=I/O error.

This will happen on every never written tape because you can not read
a blank tape.

John

-------------------------------------------------------------------------