Mel,
In case it needs to run an AUDIT LIBRARY, would it be with
CHELKLABEL=YES or CHECKLABEL=BARCODE?
Because, CHECKLABEL=YES may take hours to complete the audit as it
mounts and checks the label of each volume...
-Rama
-----Original Message-----
From: ADSM: Dist Stor Manager [mailto:ADSM-L AT VM.MARIST DOT EDU] On Behalf Of
Dennis, Melburn (IT Solutions US)
Sent: Thursday, December 06, 2007 4:04 PM
To: ADSM-L AT VM.MARIST DOT EDU
Subject: Re: [ADSM-L] ANR8314E Library is Full Error
Actually if all that was added was extra slots in the second frame, all
that needs to be run is an "audit library" command. This will force
your library to reaudit your current inventory including the new empty
slots. If new drives were added as well, just define the new paths and
drives to the existing library. No need to delete paths/drives/library
for this. I've done it several times when we've upgraded our scalar 10k
with new cabinets.
Mel Dennis
Backup Systems Engineer
Siemens IT Solutions and Services, Inc.
PGST Data Center Operations
4400 Alafaya Trail
MC Q1-108
Orlando, FL 32826
Tel.: 407-736-2360
Mob: 321-356-9366
Fax: 407-243-0260
mailto:melburn.dennis AT siemens DOT com
www.usa.siemens.com/it-solutions
-----Original Message-----
From: ADSM: Dist Stor Manager [mailto:ADSM-L AT VM.MARIST DOT EDU] On Behalf Of
Stapleton, Mark
Sent: Thursday, December 06, 2007 2:44 PM
To: ADSM-L AT VM.MARIST DOT EDU
Subject: Re: [ADSM-L] ANR8314E Library is Full Error
From: ADSM: Dist Stor Manager [mailto:ADSM-L AT VM.MARIST DOT EDU] On Behalf Of
Maura Adams
> Thanks for the info. I just heard back from IBM support and because
our
> second frame to the library was added after our original install, TSM
> does not see it. We need to take an outage and delete/define all
paths,
> library, drives and check all tapes back in. A little bit ugly.
Not ugly at all, and no outage is required if you do this at night,
since tape drives are usually quiet during that time anyway.
Write a batch file that does the following:
delete path (all tape drives)
delete path (for library)
delete drive (all tape drives)
delete library (library)
define library
define path (for library)
define drive (all tape drives)
define path (all tape drives)
checkin libv (library) search=yes status=scratch checkl=barcode
checkin libv (library) search=yes status=private checkl=barcode
Call the batch file "library_redo". Run the file as a macro.
This should all run within a minute or two. Do it while all tape drives
are quiet.
--
Mark Stapleton
Berbee (a CDW company)
System engineer
7145 Boone Avenue North, Suite 140
Brooklyn Park MN 55428-1511
763-592-5963
www.berbee.com
--------------------------------------------------------
This message w/attachments (message) may be privileged, confidential or
proprietary, and if you are not an intended recipient, please notify the
sender, do not use or share it and delete it. Unless specifically indicated,
this message is not an offer to sell or a solicitation of any investment
products or other financial product or service, an official confirmation of any
transaction, or an official statement of Merrill Lynch. Subject to applicable
law, Merrill Lynch may monitor, review and retain e-communications (EC)
traveling through its networks/systems. The laws of the country of each
sender/recipient may impact the handling of EC, and EC may be archived,
supervised and produced in countries other than the country in which you are
located. This message cannot be guaranteed to be secure or error-free. This
message is subject to terms available at the following link:
http://www.ml.com/e-communications_terms/. By messaging with Merrill Lynch you
consent to the foregoing.
--------------------------------------------------------
|