ADSM-L

Re: [ADSM-L] ANR8314E Library is Full Error

2007-12-05 10:08:08
Subject: Re: [ADSM-L] ANR8314E Library is Full Error
From: Maura Adams <Maura.Adams AT BC DOT EDU>
To: ADSM-L AT VM.MARIST DOT EDU
Date: Wed, 5 Dec 2007 10:07:23 -0500
Thanks for the info.  I just heard back from IBM support and because our
second frame to the library was added after our original install, TSM
does not see it.  We need to take an outage and delete/define all paths,
library, drives and check all tapes back in.  A little bit ugly.

Drats!

Zoltan Forray/AC/VCU wrote:
Sounds like time to do an audit of the library.

We have these kinds of issue with our "wonderful" 3583 libraries and it is
usually due to the TSM info/audit being out of sync with libraries info.
We do audits all the time, especially after we have to power-recycle the
libraries, which is at least once a week.




Maura Adams <Maura.Adams AT BC DOT EDU>
Sent by: "ADSM: Dist Stor Manager" <ADSM-L AT VM.MARIST DOT EDU>
12/05/2007 09:49 AM
Please respond to
"ADSM: Dist Stor Manager" <ADSM-L AT VM.MARIST DOT EDU>


To
ADSM-L AT VM.MARIST DOT EDU
cc

Subject
[ADSM-L] ANR8314E Library is Full Error






I've never sent to the listserv before, so we'll so how this goes.  In
short we have a IBM 3584 library. Through the specialist interface, I
can see that we have 399 slots available in the tape library.  However,
when running the checkin command on our weekly offsite tape returns, I
receive the following.

23:49:57  ANR8314E Library 7OF9 is full.


ANR0985I Process 4785 for CHECKIN LIBVOLUME running in the BACKGROUND
completed with completion state FAILURE at 23:49:57

I have opened a PMR, but am wondering if anyone else has a seen this
problem.

Maura