Re: [Networker] ADIC Scalar 24 Cleaning slots
2009-12-03 09:06:31
Hi.
I managed to switch from hardware to software cleaning control so.
Removed cleaning tape from jukebox. Rebooted JB. Switched from menu:
Autocleaning - off and Cleaning slots - 0.
Switched jukebox off, loaded manually cleaning tape to last slot, powered JB on.
Reconfigured jukebox from storage node and settings became correct: data slots:
1-22, cleaning slots: 23-23.
WBR
Anri
-----Original Message-----
From: EMC NetWorker discussion [mailto:NETWORKER AT LISTSERV.TEMPLE DOT EDU] On
Behalf Of pereubu
Sent: Tuesday, December 01, 2009 5:58 PM
To: NETWORKER AT LISTSERV.TEMPLE DOT EDU
Subject: [Networker] ADIC Scalar 24 Cleaning slots
OK, ADIC Scalar 24 jukebox has two cleaning tapes in slot 22 and 23. Slot 16-21
are empty and they are configured as data slots, while 22 and 23 are configured
as Clean slots. There two cleaning tapes-cartigaes are located there. I am
talking about LCD manual configuration on ADIC Scalar 24. "Auto Clean" Enable
to "On" on LCD.
So what you suggest is that I put one cleaning tape let say in 18? Then by LCD
manual configuration to configure "Auto Clean" disable and slot 18 is
configured as data slot (not cleaning one). That was for physical configuration
on LCD.
With the "Cleaning" tape in 18th slot NMC will recognise it as cleaning tape?
On NMC I have to put "Auto Enable" attribute to "Yes" and "Cleaning Slots"
18-18. In that case it would recognise the tape in slot 18 as cleaning tape?
+----------------------------------------------------------------------
|This was sent by aleksandar.cosic AT futuraplus DOT rs via Backup Central.
|Forward SPAM to abuse AT backupcentral DOT com.
+----------------------------------------------------------------------
To sign off this list, send email to listserv AT listserv.temple DOT edu and
type "signoff networker" in the body of the email. Please write to
networker-request AT listserv.temple DOT edu if you have any problems with this
list. You can access the archives at
http://listserv.temple.edu/archives/networker.html or
via RSS at http://listserv.temple.edu/cgi-bin/wa?RSS&L=NETWORKER
To sign off this list, send email to listserv AT listserv.temple DOT edu and
type "signoff networker" in the body of the email. Please write to
networker-request AT listserv.temple DOT edu if you have any problems with this
list. You can access the archives at
http://listserv.temple.edu/archives/networker.html or
via RSS at http://listserv.temple.edu/cgi-bin/wa?RSS&L=NETWORKER
|
|
|