OK, ADIC Scalar 24 jukebox has two cleaning tapes in slot 22 and 23. Slot 16-21
are empty and they are configured as data slots, while 22 and 23 are configured
as Clean slots. There two cleaning tapes-cartigaes are located there. I am
talking about LCD manual configuration on ADIC Scalar 24. "Auto Clean" Enable
to "On" on LCD.
So what you suggest is that I put one cleaning tape let say in 18? Then by LCD
manual configuration to configure "Auto Clean" disable and slot 18 is
configured as data slot (not cleaning one). That was for physical configuration
on LCD.
With the "Cleaning" tape in 18th slot NMC will recognise it as cleaning tape?
On NMC I have to put "Auto Enable" attribute to "Yes" and "Cleaning Slots"
18-18. In that case it would recognise the tape in slot 18 as cleaning tape?
+----------------------------------------------------------------------