ADSM-L

Re: lift blocked 3575l12 33h checkin

2001-06-27 15:02:32
Subject: Re: lift blocked 3575l12 33h checkin
From: David Longo <David.Longo AT HEALTH-FIRST DOT ORG>
Date: Wed, 27 Jun 2001 15:03:09 -0400
Cal  IBM service on this if you got the error more than once.  I have a 
3575-L32 and have had this.  On mine though it required a "special mod" from 
IBM's manufacturer due to a new "phase 3" shaft.   What was basically happening 
was the big ribbon cable connecting to the robot assy was getting partially 
caught in some instances and holding lift and damaging cable.  We actually saw 
this happen on several occaisions.

Don't know if this would be happening the same on the L12 though.  Examine the 
ribbon cable for any nicks or damage.

There can be other reasons but it is most likely library and not *SM.


David B. Longo
System Administrator
Health First, Inc.
3300 Fiske Blvd.
Rockledge, FL 32955-4305
PH      321.434.5536
Pager  321.634.8230
Fax:    321.434.5525
david.longo AT health-first DOT org


>>> k_willems AT TTP-INT DOT COM 06/27/01 02:06PM >>>
Dear Listers,

I have a problem with a 3575 l12 TSM 4.1.3 Atape 5.0.4. AIX 4.3.0.0.

When I want to run dsmadmc " checkin libvol 3575lib stat=scr search=bulk"

q req gives me a reply number and place vol in io....

then the magstar moves his picker to the top i/o slot and then.... gives 33h 
lift blocked on his console.....

If anyone can give me a hint !!

Best Regards,

Koen Willems
Touch The Progress bv
Netherlands



"MMS <health-first.org>" made the following
 annotations on 06/27/01 15:07:04
------------------------------------------------------------------------------
---
This message is for the named person's use only.  It may contain This message 
is for the named person's use only.  It may contain confidential, proprietary, 
or legally privileged information.  No confidentiality or privilege is waived 
or lost by any mistransmission.  If you receive this message in error, please 
immediately delete it and all copies of it from your system, destroy any hard 
copies of it, and notify the sender.  You must not, directly or indirectly, 
use, disclose, distribute, print, or copy any part of this message if you are 
not the intended recipient.  Health First reserves the right to monitor all 
e-mail communications through its networks.  Any views or opinions expressed in 
this message are solely those of the individual sender, except (1) where the 
message states such views or opinions are on behalf of a particular entity;  
and (2) the sender is authorized by the entity to give such views or opinions.

==============================================================================
<Prev in Thread] Current Thread [Next in Thread>