I've been working with StorageTek for a while on this, but I wanted to
see if any of you have this problem. I'm running NBU 3.2 on Sun
E450/Solaris 2.6 master/media server.  At first one, but now 2 of 3
drives on the same SCSI bus will come up, but after they're used for a
little bit, they go into a DOWN state. You can bring them up, but once
they're used they go back down. I get this messages repeatedy in
/var/adm/messages:


Feb 19 04:24:25 athena unix: glm3:      Cmd (0x60294908) dump for Target
1 Lun 0:
Feb 19 04:24:25 athena unix: glm3:              cdb=[ 0x1 0x0 0x0 0x0
0x0 0x0 ]
Feb 19 04:24:25 athena unix: glm3:      pkt_flags=0x0
pkt_statistics=0x61 pkt_state=0x7
Feb 19 04:24:25 athena unix: glm3:      pkt_scbp=0x0 cmd_flags=0xe1
Feb 19 04:24:25 athena unix: WARNING: /pci@6,4000/scsi@3,1 (glm3):
Feb 19 04:24:25 athena unix:    Disconnected command timeout for Target
1.0
Feb 19 04:24:25 athena unix: WARNING: ID[SUNWpd.glm.cmd_timeout.6016]
Feb 19 04:24:25 athena unix: WARNING: /pci@6,4000/scsi@3,1/st@1,0
(st22):
Feb 19 04:24:25 athena unix:    SCSI transport failed: reason 'timeout':
retrying command
Feb 19 04:24:25 athena unix:


STK has replaced the drive twice (!). Is this indicative of just a bad
cable? Bad hostbus adaptor?


Thanks,

RCA
--
Ryan C. Anderson        |   United Defense L.P.    
Unix Administrator      |   763.572.6684 (desk)
ryan_anderson AT udlp DOT com  |   952.235.9936 (pager)



<Prev in Thread] Current Thread [Next in Thread>