Veritas-bu

[Veritas-bu] DLT drive/cable problems

2001-02-21 10:41:53
Subject: [Veritas-bu] DLT drive/cable problems
From: Carawan-Hubin, Noel noel AT Conxion DOT net
Date: Wed, 21 Feb 2001 07:41:53 -0800
Ryan:

We had a similar problem when we upped the quatity of our drives and
reconfigured.  The drvconfig, etc, did not work, and our manual config was
in error.  We ended up downing those drives until we could reconfig.  We did
that, and now problem is solved.  Initially, we were told it was our power
fluctuating, but, since reconfig, they have been up, running, for over a
month with NONE going down.

Maybe it's the scsi config.

-NCH

-----Original Message-----
From: RYAN ANDERSON [mailto:RYAN_ANDERSON AT udlp DOT com]
Sent: Wednesday, February 21, 2001 7:35 AM
To: NBU, Veritas
Subject: [Veritas-bu] DLT drive/cable problems


I've been working with StorageTek for a while on this, but I wanted to
see if any of you have this problem. I'm running NBU 3.2 on Sun
E450/Solaris 2.6 master/media server.  At first one, but now 2 of 3
drives on the same SCSI bus will come up, but after they're used for a
little bit, they go into a DOWN state. You can bring them up, but once
they're used they go back down. I get this messages repeatedy in
/var/adm/messages:


Feb 19 04:24:25 athena unix: glm3:      Cmd (0x60294908) dump for Target
1 Lun 0:
Feb 19 04:24:25 athena unix: glm3:              cdb=[ 0x1 0x0 0x0 0x0
0x0 0x0 ]
Feb 19 04:24:25 athena unix: glm3:      pkt_flags=0x0
pkt_statistics=0x61 pkt_state=0x7
Feb 19 04:24:25 athena unix: glm3:      pkt_scbp=0x0 cmd_flags=0xe1
Feb 19 04:24:25 athena unix: WARNING: /pci@6,4000/scsi@3,1 (glm3):
Feb 19 04:24:25 athena unix:    Disconnected command timeout for Target
1.0
Feb 19 04:24:25 athena unix: WARNING: ID[SUNWpd.glm.cmd_timeout.6016]
Feb 19 04:24:25 athena unix: WARNING: /pci@6,4000/scsi@3,1/st@1,0
(st22):
Feb 19 04:24:25 athena unix:    SCSI transport failed: reason 'timeout':
retrying command
Feb 19 04:24:25 athena unix:


STK has replaced the drive twice (!). Is this indicative of just a bad
cable? Bad hostbus adaptor?


Thanks,

RCA
--
Ryan C. Anderson        |   United Defense L.P.    
Unix Administrator      |   763.572.6684 (desk)
ryan_anderson AT udlp DOT com  |   952.235.9936 (pager)
_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu