On Thu, Dec 29, 2011 at 7:27 AM, ninyo <ninyodios AT gmail DOT com> wrote:
> No one has any idea? Not pretending a solution but a ideas to make test or
> see where it can be failing.

I do not see the problem. I have just updated to 5.2.3 myself from
5.0.3 last week. However the update slots command worked fine.

*st
Status available for:
     1: Director
     2: Storage
     3: Client
     4: All
Select daemon type for status (1-4): 1
fileserver-dir Version: 5.2.3 (16 December 2011) x86_64-pc-linux-gnu gentoo
Daemon started 23-Dec-11 12:25. Jobs: run=45, running=0
 Heap: heap=1,929,216 smbytes=552,773 max_bytes=17,253,666 bufs=3,611
max_bufs=124,487

Scheduled Jobs:
Level          Type     Pri  Scheduled          Name               Volume
===================================================================================
Incremental    Backup    10  29-Dec-11 20:30    CVSSource          Other-0252
Incremental    Backup    10  29-Dec-11 20:30    Info               A00020
Incremental    Backup    10  29-Dec-11 20:30    Publics            A00020
Incremental    Backup    10  29-Dec-11 20:30    user-private       A00020
Full           Backup    10  30-Dec-11 01:10    BackupCatalog      *unknown*
====

Running Jobs:
Console connected at 26-Dec-11 00:26
No Jobs running.
====

Terminated Jobs:
 JobId  Level    Files      Bytes   Status   Finished        Name
====================================================================
 27912  Incr          0         0   OK       27-Dec-11 20:30 CVSSource
 27915  Incr          0         0   OK       27-Dec-11 20:30 Info
 27914  Incr          0         0   OK       27-Dec-11 20:30 Publics
 27913  Incr      8,711    2.309 G  OK       27-Dec-11 20:35 user-private
 27916  Full          1    3.757 G  OK       28-Dec-11 01:22 BackupCatalog
 27917  Incr          0         0   OK       28-Dec-11 20:30 CVSSource
 27919  Incr          0         0   OK       28-Dec-11 20:30 Publics
 27920  Incr          0         0   OK       28-Dec-11 20:30 Info
 27918  Incr      8,583    2.341 G  OK       28-Dec-11 20:37 user-private
 27921  Full          1    3.758 G  OK       29-Dec-11 01:22 BackupCatalog

====
*update slots
The defined Storage resources are:
     1: File
     2: DLT-IV
     3: DVD-FILESERVER
     4: DEV6-DLT-IV-0
     5: DEV6-LTO-0
     6: DEV6-LTO2-1
     7: DEV6-Changer
Select Storage resource (1-7): 7
Connecting to Storage daemon DEV6-Changer at dev6.radimg.pitt.edu:9103 ...
3306 Issuing autochanger "slots" command.
Device "Magnum224-0" has 24 slots.
Connecting to Storage daemon DEV6-Changer at dev6.radimg.pitt.edu:9103 ...
3306 Issuing autochanger "list" command.
Catalog record for Volume "A00104" updated to reference slot 1.
Catalog record for Volume "A00106" updated to reference slot 2.
Catalog record for Volume "A00108" updated to reference slot 3.
Catalog record for Volume "A00107" updated to reference slot 4.
Catalog record for Volume "A00023" updated to reference slot 5.
Catalog record for Volume "A00101" updated to reference slot 6.
Catalog record for Volume "A00072" updated to reference slot 7.
Catalog record for Volume "A00102" updated to reference slot 8.
Catalog record for Volume "A00028" updated to reference slot 9.
Catalog record for Volume "A00109" updated to reference slot 10.
Catalog record for Volume "A00054" updated to reference slot 11.
Catalog record for Volume "A00039" updated to reference slot 12.
Catalog record for Volume "A00073" updated to reference slot 13.
Catalog record for Volume "A00012" updated to reference slot 14.
Catalog record for Volume "A00097" updated to reference slot 15.
Catalog record for Volume "A00020" updated to reference slot 16.
Catalog record for Volume "A00074" updated to reference slot 17.
Catalog record for Volume "A00096" updated to reference slot 18.
Catalog record for Volume "A00030" updated to reference slot 19.
Catalog record for Volume "A00100" updated to reference slot 20.
Catalog record for Volume "A00095" updated to reference slot 21.
Catalog record for Volume "A00053" updated to reference slot 22.
Catalog record for Volume "A00036" updated to reference slot 23.
Catalog record for Volume "A00056" updated to reference slot 24.
You have messages.
*

------------------------------------------------------------------------------
Ridiculously easy VDI. With Citrix VDI-in-a-Box, you don't need a complex
infrastructure or vast IT resources to deliver seamless, secure access to
virtual desktops. With this all-in-one solution, easily deploy virtual 
desktops for less than the cost of PCs and save 60% on VDI infrastructure 
costs. Try it free! http://p.sf.net/sfu/Citrix-VDIinabox
_______________________________________________
Bacula-users mailing list
Bacula-users AT lists.sourceforge DOT net
https://lists.sourceforge.net/lists/listinfo/bacula-users