Bacula-users

Re: [Bacula-users] continuing a failed job

2010-01-07 03:48:01
Subject: Re: [Bacula-users] continuing a failed job
From: Uwe Schuerkamp <hoover AT nionex DOT net>
To: Phil Stracchino <alaric AT metrocast DOT net>
Date: Thu, 7 Jan 2010 09:45:27 +0100
On Wed, Jan 06, 2010 at 12:52:44PM -0500, Phil Stracchino wrote:

> My first inclination is to say that if the network connection to the
> machine is sufficiently unstable that you can't complete a full backup,
> you probably shouldn't be trying to back it up over the network.
> However, there are ways to work around the problem.
> 

You could also try rsync'ing (rsync -av user@remotehost:/
/backup/remote_host/) to a local filesystem and then backing
that copy up locally. Should rsync abort it will skip the files which
are already present & up to date on the local copy. 

HTH, Uwe 



-- 
uwe.schuerkamp AT nionex DOT net fon: [+49] 5242.91 - 4740, fax:-69 72
Hauptsitz: Avenwedder Str. 55, D-33311 Gütersloh, Germany