Re: [Bacula-users] After upgrade to 3.0.1: Concurrentjobs fail (The number of files mismatch)
2009-05-12 11:11:59
Am 12.05.2009 15:49, schrieb user100:
Am 12.05.2009 14:05, schrieb Christian Gaul:
user100 schrieb:
Am 12.05.2009 09:34, schrieb Christian Gaul:
In case it helps, i turned my tape drives to maximum concurrent jobs 1
and so far it hasnt happened anymore, but i dont know if that was
just luck.
Yesterday I changed "Maximum Concurrent Jobs = 1" in the director and
this night all backups finished successfully. So it´s devinitively
using concurrent Jobs that causes that mismatch and it did not occur
until I upgraded to 3.0.1 so I think it´s a bug in that version.
Greetings,
user100
Since the same thing worked for us both i'm curious, are you using
attribute / data spooling?
Yes, I use spooling but I disabled it now for a test. The result was
the same: "The number of files mismatch". So I think spooling is not
the reason.
Greetings,
user100
I just tested again concurrent jobs but this time I used filestorage
instead of autochanger/tape. It failed with filestorage too! Just the
failuremessage differs a little bit:
12-May 16:38 swlinbck2-sd JobId 21019: Volume "tmp1" previously
written, moving to end of data.
12-May 16:38 swlinbck2-sd JobId 21019: Error: Bacula cannot write on
disk Volume "tmp1" because: The sizes do not match! Volume=393523396
Catalog=207
12-May 16:38 swlinbck2-sd JobId 21019: Marking Volume "tmp1" in Error
in Catalog.
12-May 16:38 swlinbck2-sd JobId 21019: Job
swtemp01.2009-05-12_16.38.28_04 waiting. Cannot find any appendable
volumes.
But again even with filestorage: When I run just one job and wait until
that job finished to start the next job it´s working. Just concurrent
jobs fail.
Greetings,
user100
|
------------------------------------------------------------------------------
The NEW KODAK i700 Series Scanners deliver under ANY circumstances! Your
production scanning environment may not be a perfect world - but thanks to
Kodak, there's a perfect scanner to get the job done! With the NEW KODAK i700
Series Scanner you'll get full speed at 300 dpi even with all image
processing features enabled. http://p.sf.net/sfu/kodak-com _______________________________________________
Bacula-users mailing list
Bacula-users AT lists.sourceforge DOT net
https://lists.sourceforge.net/lists/listinfo/bacula-users
|
|
|