Hi everybody,
I am trying to figure out what is happening with my backups. I don't
think the problem is with bacula, but I thought I'd ask here in case
someone experienced the same problem.
I am using a HP Ultrium-3 auto loader, but not using the autochanger
feature, just manually changing the tapes when needed.
The full backups are done using 800GB(2:1 compression) LTO-3 tapes. My
full backups are just under 300GB, but sometimes bacula thinks the tape
is full after writing about 230GB to it and requests a new tape.
I have enabled hardware compression, but it still writes less than the
uncompressed capacity of the tape.
Any clues on what might be causing this ?
Below are some information.
Thanks
Bruno
[root@dracula bacula]# tapeinfo -f /dev/sg0
Product Type: Tape Drive
Vendor ID: 'HP '
Product ID: 'Ultrium 3-SCSI '
Revision: 'D22W'
Attached Changer API: No
SerialNumber: 'HU10802KLK'
MinBlock: 1
MaxBlock: 16777215
SCSI ID: 4
SCSI LUN: 0
Ready: yes
BufferedMode: yes
Medium Type: Not Loaded
Density Code: 0x42
BlockSize: 0
DataCompEnabled: yes
DataCompCapable: yes
DataDeCompEnabled: yes
CompType: 0x1
DeCompType: 0x1
Block Position: 378367
Partition 0 Remaining Kbytes: 200448
Partition 0 Size in Kbytes: 200448
ActivePartition: 0
EarlyWarningSize: 0
NumPartitions: 0
MaxPartitions: 0
bacula-sd.conf:
Device {
Name = StorageWorks
Media Type = LTO
Archive Device = /dev/nst0
AutomaticMount = yes
AlwaysOpen = no
RemovableMedia = yes
RandomAccess = no
AutoChanger = no
#Changer Command = "/usr/lib64/bacula/mtx-changer %c %o %S %a d"
#Changer Device = /dev/sg1
Alert Command = "sh -c 'smartctl -H -l error /dev/nst0'"
Spool Directory = /var/spool/bacula
Maximum Spool Size = 50GB
HP LTT:
Product ID : Ultrium 3-SCSI
Drive Technology : LTO
Mech. Serial Number : HU10802KLK
Firmware Rev : D22W/MSL G3/1x8 G2
Target ID : 4
Target LUN : 0
OBDR Capability : Not Present
WORM Capability : Present
Cartridge Information (for cartridge currently in drive):
Cartridge Type : LTO 3 Data
* Capacity : 800 GB (assumes 2:1 data compression)
Write Protected : No
Serial ID : SLOT0000
30-Dec 05:30 dracula-dir JobId 877: Start Backup JobId 877,
Job=rhino.2008-12-29_22.00.32
30-Dec 05:33 dracula-dir JobId 877: Using Device "StorageWorks"
30-Dec 05:33 dracula-sd JobId 877: Spooling data ...
30-Dec 07:03 dracula-sd JobId 877: User specified spool size reached.
30-Dec 07:03 dracula-sd JobId 877: Writing spooled data to Volume.
Despooling 27,811,908,212 bytes ...
30-Dec 07:14 dracula-sd JobId 877: Despooling elapsed time = 00:10:57,
Transfer rate = 42.33 M bytes/second
30-Dec 07:15 dracula-sd JobId 877: Spooling data again ...
30-Dec 09:50 dracula-sd JobId 877: User specified spool size reached.
30-Dec 09:50 dracula-sd JobId 877: Writing spooled data to Volume.
Despooling 50,000,033,648 bytes ...
30-Dec 10:10 dracula-sd JobId 877: Despooling elapsed time = 00:19:42,
Transfer rate = 42.30 M bytes/second
30-Dec 10:11 dracula-sd JobId 877: Spooling data again ...
30-Dec 12:24 dracula-sd JobId 877: Job write elapsed time = 06:50:55,
Transfer rate = 4.968 M bytes/second
30-Dec 12:24 dracula-sd JobId 877: Committing spooled data to Volume
"NIX-DME-DEC-2008". Despooling 44,805,130,929 bytes ...
30-Dec 12:24 dracula-sd JobId 877: Error: block.c:568 Write error at
226:14539 on device "StorageWorks" (/dev/nst0). ERR=Input/output error.
30-Dec 12:24 dracula-sd JobId 877: Error: Re-read of last block OK, but
block numbers differ. Last block=774904 Current block=1.
30-Dec 12:24 dracula-sd JobId 877: End of medium on Volume
"NIX-DME-DEC-2008" Bytes=223,406,346,240 Blocks=3,463,019 at 30-Dec-2008
12:24.
30-Dec 12:24 dracula-sd JobId 877: Job rhino.2008-12-29_22.00.32
waiting. Cannot find any appendable volumes.
Please use the "label" command to create a new Volume for:
Storage: "StorageWorks" (/dev/nst0)
Pool: NIX-DME-MONTHLY
Media type: LTO
New to NET-A-PORTER.COM: 6 fabulous boutiques!
http://www.net-a-porter.com/boutiques
______________________________________________________________________
CONFIDENTIALITY NOTICE
The information in this email is confidential and is intended solely for the
addressee. Access to this email by anyone else is unauthorised. If you are not
the intended recipient, you must not read, use or disseminate the information.
Any views expressed in this message are those of the individual sender, except
where the sender specifically states them to be the views of Net a Porter Ltd.
Net A Porter Ltd is a company registered in England & Wales Number: 3820604
Registered Office: The Dome, Whiteleys Centre, 151 Queensway, London, W2 4YN.
_____________________________________________________________________
------------------------------------------------------------------------------
_______________________________________________
Bacula-users mailing list
Bacula-users AT lists.sourceforge DOT net
https://lists.sourceforge.net/lists/listinfo/bacula-users
|