Saving data on a defective cartridge
2003-09-18 10:14:45
Hello,
I just found a way to partially recover data on a defective 3590 cartridge.
Move data and audit volume aborted when processing a specific file.
Unfortunately, this was very near to the beginning of the tape. So I was
afraid to lose about 10 GB of data.
I started del vol discard=yes. Then I got a new idea. The discard is a
background process which can be cancelled. I cancelled it and ran audit
volume. Everything was fine because the offendig file was deleted!
Unfortunately, 17000 files and 1.7 GB are lost because the idea came too
late. I should have cancelled the process much earlier. In case you have the
same problem I hope you will remember this mail and cancel the discard
process earlier.
Or is there an even better method?
Best regards
Gerhard
---
Gerhard Rentschler email:g.rentschler AT rus.uni-stuttgart DOT de
Regional Computing Center tel. ++49/711/685 5806
University of Stuttgart fax: ++49/711/682357
Allmandring 30a
D 70550
Stuttgart
Germany
|
<Prev in Thread] |
Current Thread |
[Next in Thread>
|
- Saving data on a defective cartridge,
Gerhard Rentschler <=
|
|
|