Re: Saving data on a defective cartridge
2003-09-18 12:35:52
Try doing a move data to get the data off of the tape. If I find I am
starting to have problems I usually do a:
update vol VOLUMENAME acc=reado
move data VOLUMENAME
This should move all data that is recoverable from the volume to another
volume in the same storage pool. I then eject the offending volume and
check it for apparent physical issues. Then the part I hate:
delete vol VOLUMENAME discarddata=yes
Sometimes I am able to re-label the volume and use it again. But
typically it gets moved to a less critical use, returned to the vendor
for a new tape [my preferred method], or degaused and distroyed by
a certified vendor [least preferred, paying to have it thrown away].
If anyone has a better method, please let me know! ... JC
-----Original Message-----
From: Gerhard Rentschler [mailto:g.rentschler AT RUS.UNI-STUTTGART DOT DE]
Sent: Thursday, September 18, 2003 11:24 AM
To: ADSM-L AT VM.MARIST DOT EDU
Subject: Re: Saving data on a defective cartridge
Hello,
I forgot to mention that because of lack of resources I can't afford a
copypool for the backup files. I have one for the archives.
Best regards
Gerhard
---
Gerhard Rentschler email:g.rentschler AT rus.uni-stuttgart DOT de
Regional Computing Center tel. ++49/711/685 5806
University of Stuttgart fax: ++49/711/682357
Allmandring 30a
D 70550
Stuttgart
Germany
> -----Original Message-----
> From: ADSM: Dist Stor Manager [mailto:ADSM-L AT VM.MARIST DOT EDU]On Behalf Of
> Juan Manuel Lopez Azanon
> Sent: Thursday, September 18, 2003 6:02 PM
> To: ADSM-L AT VM.MARIST DOT EDU
> Subject: Re: Saving data on a defective cartridge
>
>
> Disaster recovery management: Restore it from outside volumes from copy
> stgpool
>
|
<Prev in Thread] |
Current Thread |
[Next in Thread>
|
- Saving data on a defective cartridge, Gerhard Rentschler
- Re: Saving data on a defective cartridge, Juan Manuel Lopez Azañon
- Re: Saving data on a defective cartridge, Richard Sims
- Re: Saving data on a defective cartridge,
Coats, Jack <=
- Re: Saving data on a defective cartridge, Wholey, Joseph (IDS DM&DS)
- Re: Saving data on a defective cartridge, Tom Kauffman
- Re: Saving data on a defective cartridge, Richard Sims
- Re: Saving data on a defective cartridge, Steve Harris
- Re: Saving data on a defective cartridge, Pole, Stephen
- Re: Saving data on a defective cartridge, Prather, Wanda
- Re: Saving data on a defective cartridge, Tab Trepagnier
|
|
|