Veritas-bu

[Veritas-bu] Tape drives not seen - fibre channel config

2009-05-28 19:29:20
Subject: [Veritas-bu] Tape drives not seen - fibre channel config
From: Jeff Cleverley <jeff.cleverley AT avagotech DOT com>
To: veritas-bu AT mailman.eng.auburn DOT edu
Date: Thu, 28 May 2009 17:24:19 -0600
Greetings,

I know this isn't a specific Veritas question but I'm guessing someone may have run into this problem while setting up a new installation.

I'm trying to get a new 6.5.3 installation ready for some testing on a linux RHEL 4.5 server using a qlogic QLE2462 card.  The tape libraries are HP/Compac MSL6000 libraries with Ultrium 2 drives and the e1200-160 fibre bridges.  For this test I'm using a Brocade 3800 silkworm.

The problem that I have is nothing past the robotic controller gets recognized on one bridge.  The robotic is lun 0, and then drives at lun 1 and lun 2. 

Is there some lun mapping or instance type issues associated with linux or any of the pieces I'm trying to put into place?  The output of /proc/scsi/qla2xxx/0 is below.  You can see it sees both targets but luns 0-2 on Id 0 say they are not registered for some reason.  Lun 3 is the robotic controller but the fibre bridge actually has the robot as lun 0.  I'm not sure why it shows up here as 3.

QLogic PCI to Fibre Channel Host Adapter for QLE2462:
        Firmware version 4.04.00 [IP] [84XX] , Driver version 8.02.14.01
BIOS version 1.08
FCODE version 1.13
EFI version 1.02
Flash FW version 4.00.12 0002
ISP: ISP2432
Request Queue = 0x3d980000, Response Queue = 0x3d950000
Request Queue count = 4096, Response Queue count = 512
Total number of active commands = 0
Total number of interrupts = 3661
    Device queue depth = 0x10
Number of free request entries = 3993
Number of mailbox timeouts = 0
Number of ISP aborts = 0
Number of loop resyncs = 0
Number of retries for empty slots = 0
Number of reqs in pending_q= 0, retry_q= 0, done_q= 0, scsi_retry_q= 0
Host adapter:loop state = <READY>, flags = 0x5a43
Dpc flags = 0x0
MBX flags = 0x0
Link down Timeout = 045
Port down retry = 045
Login retry count = 045
Commands retried with dropped frame(s) = 0
Product ID = 0000 0000 0000 0000

SCSI Device Information:
scsi-qla0-adapter-node=2000001b3206c267;
scsi-qla0-adapter-port=2100001b3206c267;
scsi-qla0-target-0=100000e00222ddf1;
scsi-qla0-target-1=100000e00222efa0;

FC Port Information:
scsi-qla0-port-0=100000e00202ddf1:100000e00222ddf1:010d00:81;
scsi-qla0-port-1=100000e00202efa0:100000e00222efa0:010e00:82;

SCSI LUN Information:
(Id:Lun)  * - indicates lun is not registered with the OS.
( 0: 0): Total reqs 3, Pending reqs 0, flags 0x0*, Dflags 0x0, 0:0:81 08
( 0: 1): Total reqs 0, Pending reqs 0, flags 0x0*, Dflags 0x0, 0:0:81 01
( 0: 2): Total reqs 0, Pending reqs 0, flags 0x0*, Dflags 0x0, 0:0:81 01
( 0: 3): Total reqs 0, Pending reqs 0, flags 0x0, Dflags 0x0, 0:0:81 0c
( 1: 0): Total reqs 9, Pending reqs 0, flags 0x0, Dflags 0x0, 0:0:82 01
( 1: 1): Total reqs 7, Pending reqs 0, flags 0x0, Dflags 0x0, 0:0:82 01
( 1: 2): Total reqs 2, Pending reqs 0, flags 0x0, Dflags 0x0, 0:0:82 0c

Any ideas why the system isn't seeing the drives on ID 0?  The library I'm zoning into for these tests is a production box so I don't have the option of changing ID's on the fibre bridge.

Thanks,

Jeff
-- 

Jeff Cleverley
Unix Systems Administrator
4380 Ziegler Road
Fort Collins, Colorado 80525
970-288-4611
jeff.cleverley AT avagotech DOT com
_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
<Prev in Thread] Current Thread [Next in Thread>
  • [Veritas-bu] Tape drives not seen - fibre channel config, Jeff Cleverley <=