[Veritas-bu] tape drive changed
2006-11-20 15:16:47
Subject: |
[Veritas-bu] tape drive changed |
From: |
Brandon.Zermeno at Pulte.com (Brandon Zermeno) |
Date: |
Mon, 20 Nov 2006 13:16:47 -0700 |
>From volmgr\bin run vmglob -delete -drive -serial (case sensitive serial
number of old drive here) -devhost servername
After that the old drive is gone then I just run the device manager
wizard for that server again.
-----Original Message-----
From: veritas-bu-bounces at mailman.eng.auburn.edu
[mailto:veritas-bu-bounces at mailman.eng.auburn.edu] On Behalf Of Krzys
Sent: Monday, November 20, 2006 11:28 AM
To: veritas-bu at mailman.eng.auburn.edu
Subject: [Veritas-bu] tape drive changed
I am running NB 6.0 MP3, I just replaced tape drive, what do I need to
do in
netbackup to recognize this tape drive and use it? I did hear that
devices in
netbackup are using drive serial numbers?
Thanks for any help.
Chris
_______________________________________________
Veritas-bu maillist - Veritas-bu at mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
CONFIDENTIALITY NOTICE: This email may contain confidential and privileged
material for the sole use of the intended recipient(s). Any review, use,
distribution or disclosure by others is strictly prohibited. If you have
received this communication in error, please notify the sender immediately by
email and delete the message and any file attachments from your computer.
Thank you.
|
|
|