Subject: [Veritas-bu] tape drive changed
From: Brandon.Zermeno at Pulte.com (Brandon Zermeno)
Date: Mon, 20 Nov 2006 13:16:47 -0700
>From volmgr\bin run vmglob -delete -drive -serial (case sensitive serial
number of old drive here) -devhost servername

After that the old drive is gone then I just run the device manager
wizard for that server again. 

-----Original Message-----
From: veritas-bu-bounces at mailman.eng.auburn.edu
[mailto:veritas-bu-bounces at mailman.eng.auburn.edu] On Behalf Of Krzys
Sent: Monday, November 20, 2006 11:28 AM
To: veritas-bu at mailman.eng.auburn.edu
Subject: [Veritas-bu] tape drive changed

I am running NB 6.0 MP3, I just replaced tape drive, what do I need to
do in 
netbackup to recognize this tape drive and use it? I did hear that
devices in 
netbackup are using drive serial numbers?

Thanks for any help.

Chris