Hello Jochen
I think that NET_BUFFER_SZ plays at part in duplicate as it can be done
between two media servers
Regards
Michael
On Fri, 26 Aug 2005 08:41:43 +0200, Jochen Pressler wrote
> Hi,
>
> We have a strange performance issue with staging from Disk to Tape.
>
> Config:
> Sun V440 as Master/Media Server
> Storagetek FlexLine640 used as Staging Device
> Storagetek L700 w. LTO3
>
> SIZE_DATA_BUFFERS 2048k
> NUMBER_DATA_BUFFERS 16
> SIZE_DATA_BUFFERS_DISK 2048k
> NUMBER_DATA_BUFFERS_DISK 16
>
> When we use the Flex640 as a "normal" Storage and doing Backups from
> Disk to the L700 Storage,
> we see ~140MB/sec. throughput to one LTO3 (higher than expected).
>
> When we use the same Volume on the Flex640 as an Disk Staging Unit
> an do manual relocate to 1 LTO3 we only see ~70MB/sec.
>
> When we are using two staging units on the flex and are staging to 2
> LTO3 we see ~50MB/sec. per drive.
> An overall of 100MB/sec.
>
> Since Staging is done via bpduplicate, are there any settings that
> are staging, or bpduplicate specific? It looks like that there is an
> "internal" limit, because tape, disk and system have spare resources
> left (enough idle time)
>
> do you have an ideas?
>
> thx
> Jochen
>
> --
> -----------------------------------------------------------------
> Jochen Pressler
>
> Bacher Systems EDV GmbH
> Clemens-Holzmeister-Strasse 4 , A-1100 Wien, Business Park Vienna,
> phone: +43 (1) 60 126-34 | fax: +43 (1) 60 126-4
> jo AT bacher DOT at | http://www.bacher.at
>
> Sun Certified Professional
> Veritas Certified Professional
>
> _______________________________________________
> Veritas-bu maillist - Veritas-bu AT mailman.eng.auburn DOT edu
> http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
--
Cybercity Webhosting (http://www.cybercity.dk)
|