Re: [Networker] LTO2 drives trying to load LTO3 tapes
2006-04-24 11:48:29
I've seen simular problems with a mixed SDLT and LTO library. Legato
simply would not mount a tape when it could not read the barcode of the
tape in a mixed environment. The barcode ends with the type of tape (S =
SDLT, L2 = LTO2, etc.).
In my case I was performing a disaster recovery test at a DR service
provider and had to use their library (StorageTek). We used barcode labels
compatible with HP MSL5000 series libraries, which could not be read by
the StorageTek library. As such Legato (v6.1.x) could not obtain the
barcode information from the library and refused to load a tape. We
replaced our barcode labels with standard ones, after which the problem
was solved (ofcourse the digital label did not match the barcode label,
but that was not a problem)
To sign off this list, send email to listserv AT listserv.temple DOT edu and
type "signoff networker" in the
body of the email. Please write to networker-request AT listserv.temple DOT edu
if you have any problems
wit this list. You can access the archives at
http://listserv.temple.edu/archives/networker.html or
via RSS at http://listserv.temple.edu/cgi-bin/wa?RSS&L=NETWORKER
|
|
|