Dear Team,
I have a installed and running setup of Bacula 5.2.12 with IBM LTO4 tape library. During my scheduled jobs I am getting bellow error very frequently.
17-Sep 14:15 backup-sd JobId 84: No slot defined in catalog (slot=0) for Volume "WEB0018" on "Tape-0" (/dev /IBMtape0).
17-Sep 14:15 backup-sd JobId 84: Cartridge change or "update slots" may be required.
17-Sep 14:15 backup-sd JobId 84: Warning: mount.c:217 Open device "Tape-0" (/dev /IBMtape0) Volume "WEB0018" failed: ERR=dev.c:513 Unable to open device "Tape-0" (/dev /IBMtape0): ERR=No
medium found
17-Sep 14:15 backup-sd JobId 84: Please mount Volume "WEB0018" or label a new one for:
Job: FullBackupConfig.2013-09-17_14.05.00_57
Storage: "Tape-0" (/dev /IBMtape0)
Pool: WEB
Media type: LTO-4
After this error job is in running state always and showing this message again and again. Below is the output of list media command after this error.
--+---------------------+
| MediaId | VolumeName | VolStatus | Enabled | VolBytes | VolFiles | VolRetention | Recycle | Slot | InChanger | MediaType | LastWritten |
+---------+------------+-----------+---------+----------------+----------+--------------+---------+------+-----------+-----------+---------------------+
| 10 | A00044L4 |
Error | 1 | 26,583,782,400 | 8 | 7,776,000 | 1 | 5 | 1 | LTO-4 | 2013-09-15 18:10:54 |
Previously I have removed this error by deleting volume and labeling a new slot in the pool.
*delete volume= A00044L4
*label barcodes slot=XXX pool=XXX
Please tell me exact cause and a proper remedy for this issue. And one more think in
list media command job has marked volume as a Error vol. Will I be able to restore my backup from this volume or not If yes then how.
With Regards,