Bacula-users

Re: [Bacula-users] Autochanger Problems since upgrading to 5.2.x

2012-06-06 05:25:24
Subject: Re: [Bacula-users] Autochanger Problems since upgrading to 5.2.x
From: Uwe Schuerkamp <uwe.schuerkamp AT nionex DOT net>
To: Steve O'Brien <steve.obrien AT hdesd DOT org>
Date: Wed, 6 Jun 2012 11:22:55 +0200
On Tue, Jun 05, 2012 at 02:37:56PM -0700, Steve O'Brien wrote:
> I had a fully working 5.0.1 installation with my Quantum Scalar i40 library 
> that has 2 drives, after upgrading to 5.2.3 my backups started failing, I 
> then upgraded to 5.2.6 hoping that something had been fixed no such luck.
> 
> What it looks like is that bacula is not properly unloading the tape, or not 
> waiting long enough and then it is putting the autoloader into an error state:
> A host issued a SCSI Prevent/Allow Media Removal command which is preventing 
> the drive from unloading a tape cartridge.
> 
> I can operate the loader and drive manually using mtx and mt.
> 
> Has anyone had problems with 5.2.X and their autochanger, I have tried some 
> of the settings in mtx-changer.conf but nothing seems to help

Hi Steve, 

have to tried fiddling with the max changer wait variable? I had to
adjust this one recently when we installed a new changer that took a
while longer to change tapes. 

All the best, 
Uwe 


------------------------------------------------------------------------------
Live Security Virtual Conference
Exclusive live event will cover all the ways today's security and 
threat landscape has changed and how IT managers can respond. Discussions 
will include endpoint security, mobile security and the latest in malware 
threats. http://www.accelacomm.com/jaw/sfrnl04242012/114/50122263/
_______________________________________________
Bacula-users mailing list
Bacula-users AT lists.sourceforge DOT net
https://lists.sourceforge.net/lists/listinfo/bacula-users