I have a autoloader that has two drives in it. For some reason, Drive1 is only being utilized and jobs are being backlogged in the que without taking advantage of the other drives. Any ideas why this might be? I’ve included info from bconsole and bacula-sd.conf.
Thanks!
JJ
Bacula-sd.conf
Autochanger {
Name = ADIC_Scalar_24
Device = Drive1
Device = Drive2
Changer Device = /dev/sg3
Changer Command = "/etc/bacula/mtx-changer %c %o %S %a %d"
}
Device {
Name=Drive1
Media Type = LTO2
Archive Device = /dev/st0
Autochanger = yes
AutomaticMount = yes;
AlwaysOpen = yes;
LabelMedia = no;
RemovableMedia = yes;
Random Access = no;
}
Device {
Name=Drive2
Media Type = LTO2
Archive Device = /dev/st1
Autochanger = yes
AutomaticMount = yes;
AlwaysOpen = yes;
LabelMedia = no;
RemovableMedia = yes;
Random Access = no;
}
Bconsole.
…
Device status:
Autochanger "ADIC_Scalar_24" with devices:
"Drive1" (/dev/st0)
"Drive2" (/dev/st1)
Device "Drive1" (/dev/st0) is mounted with:
Volume: KL0410
Pool: Onsite
Media type: LTO2
Device is being initialized.
Slot 17 is loaded in drive 0.
Total Bytes Read=0 Blocks Read=0 Bytes/block=0
Positioned at File=0 Block=0
Device "Drive2" (/dev/st1) is not open.
Slot 17 is loaded in drive 0.
Device "FileStorage" (/tmp) is not open.
Jeremiah Jester