Re: [Bacula-users] Still InChanger issue
2008-10-28 09:35:39
A workaround I have found is to set the slot number to 0 (using update volumes);
thus, when restoring, bacula finds a bad slot number and asks immediately for
intervention:
> 28-Oct 07:59 fn-archnfs-sd JobId 274: Invalid slot=0 defined in catalog for
> Volume "NF0020L3" on "Drive-1" (/dev/nst0). Manual load may be required.
> 28-Oct 07:59 fn-archnfs-sd JobId 274: Please mount Volume "NF0020L3" for:
> Job: RestoreFiles.2008-10-28_07.59.04
> Storage: "Drive-1" (/dev/nst0)
> Pool: Data
> Media type: LTO4
I have submitted this problem to bugs.bacula.org
Another problem I notice is that I cannot cancel the restoration job when it is
waiting for the mount.
Brgds
Olivier
Thomas a écrit :
> i can confirm this problem,
> bacula loads the slot where the tape is last seen,
> even if the inchanger flag ist set to 0.
> (you can find more about my problem in "Re: [Bacula-users] Restore Bug?" on
> 20.10.2008.)
>
> i think this is a bug.
>
> Best Regards
>
> Thomas
-------------------------------------------------------------------------