Hello,

I am using bacula-2.4.3-1

I have autochanger (HP MSL2024) with barcodes.
tapes are labeled with "label barcode"

everything is working well, but if i remove a tape
  from the library and do not replace it with a new tape,
  the old volume has not its 'InChanger' flag reset.
This causes a lot of problems (error when restoring...)

*umount storage=MSL2024
3307 Issuing autochanger "unload slot 1, drive 0" command.
3002 Device "Drive-1" (/dev/nst0) unmounted.

*list volume=NF0018L3
+---------+------------+-----------+---------+-------------+----------+--------------+---------+------+-----------+-----------+---------------------+
| MediaId | VolumeName | VolStatus | Enabled | VolBytes    | VolFiles | 
VolRetention | Recycle | Slot | InChanger | MediaType |
LastWritten         |
+---------+------------+-----------+---------+-------------+----------+--------------+---------+------+-----------+-----------+---------------------+
|       1 | NF0018L3   | Used      |       1 | 239,920,128 |        2 |      
176,400 |       1 |    1 |         1 | LTO4      |
2008-10-24 13:35:04 |
+---------+------------+-----------+---------+-------------+----------+--------------+---------+------+-----------+-----------+---------------------+

I now remove the tape from the library

*update slots storage=MSL2024
Connecting to Storage daemon MSL2024 at fn-archnfs:9103 ...
3306 Issuing autochanger "slots" command.
Device "MSL2024" has 24 slots.
Connecting to Storage daemon MSL2024 at fn-archnfs:9103 ...
3306 Issuing autochanger "list" command.
Catalog record for Volume "NF0024L3" is up to date.
Catalog record for Volume "NF0020L3" is up to date.
Catalog record for Volume "NF0028L3" is up to date.
Catalog record for Volume "CL0001CU" is up to date.

the tape is no more in the changer
but the InChanger flag for the tape is still 1

*list volume=NF0018L3
+---------+------------+-----------+---------+-------------+----------+--------------+---------+------+-----------+-----------+---------------------+
| MediaId | VolumeName | VolStatus | Enabled | VolBytes    | VolFiles | 
VolRetention | Recycle | Slot | InChanger | MediaType |
LastWritten         |
+---------+------------+-----------+---------+-------------+----------+--------------+---------+------+-----------+-----------+---------------------+
|       1 | NF0018L3   | Used      |       1 | 239,920,128 |        2 |      
176,400 |       1 |    1 |         1 | LTO4      |
2008-10-24 13:35:04 |
+---------+------------+-----------+---------+-------------+----------+--------------+---------+------+-----------+-----------+---------------------+

all operations on this tape will now fail

It seems that this bug had been solved a very long time ago.
Is there something i miss ?

Thx for help





-------------------------------------------------------------------------
This SF.Net email is sponsored by the Moblin Your Move Developer's challenge
Build the coolest Linux based applications with Moblin SDK & win great prizes
Grand prize is a trip for two to an Open Source event anywhere in the world
http://moblin-contest.org/redirect.php?banner_id=100&url=/
_______________________________________________
Bacula-users mailing list
Bacula-users AT lists.sourceforge DOT net
https://lists.sourceforge.net/lists/listinfo/bacula-users