> Hi,
> 
> Always when I do a restore the next backup causes this error. I  
> already added
> 
> tape-config-list=
> "EXABYTE VXA-2", "Exabyte VXA-2", "VXA-2";
> VXA-2 = 1,0x36,0,0x19e39,2,0x80,0x81,1;
> 
> to the Solaris 10 file /kernel/drv/st.conf to fix a problem when the  
> end of tape is reached.
> 
> 30-Sep 21:21 chet-dir JobId 584: Start Backup JobId 584,  
> Job=Logs_Job_Chet.2008-09-30_21.21.03
> 30-Sep 21:21 chet-dir JobId 584: Using Device "ExabyteVXA-2Drive"
> 30-Sep 21:21 chet-sd JobId 584: 3307 Issuing autochanger "unload slot  
> 10, drive 0" command.
> 30-Sep 21:21 chet-sd JobId 584: 3304 Issuing autochanger "load slot 4,  
> drive 0" command.
> 30-Sep 21:22 chet-sd JobId 584: 3305 Autochanger "load slot 4, drive  
> 0", status is OK.
> 30-Sep 21:22 chet-sd JobId 584: 3301 Issuing autochanger "loaded?  
> drive 0" command.
> 30-Sep 21:22 chet-sd JobId 584: 3302 Autochanger "loaded? drive 0",  
> result is Slot 4.
> 30-Sep 21:22 chet-sd JobId 584: Volume "A0000004" previously written,  
> moving to end of data.
> 30-Sep 21:40 chet-sd JobId 584: Error: Unable to position to end of  
> data on device "Exabyte VXA-2 Drive" (/dev/rmt/0cbn): ERR=dev.c:1326  
> read error on "Exabyte VXA-2 Drive" (/dev/rmt/0cbn). ERR=I/O error.
> 
> 30-Sep 21:40 chet-sd JobId 584: Marking Volume "A0000004" in Error in  
> Catalog.
> 30-Sep 21:41 chet-dir JobId 584: Recycled volume "A0000005"
> 30-Sep 21:41 chet-sd JobId 584: 3307 Issuing autochanger "unload slot  
> 4, drive 0" command.
> 30-Sep 21:43 chet-sd JobId 584: 3304 Issuing autochanger "load slot 5,  
> drive 0" command.
> 30-Sep 21:43 chet-sd JobId 584: 3305 Autochanger "load slot 5, drive  
> 0", status is OK.
> 30-Sep 21:43 chet-sd JobId 584: 3301 Issuing autochanger "loaded?  
> drive 0" command.
> 30-Sep 21:43 chet-sd JobId 584: 3302 Autochanger "loaded? drive 0",  
> result is Slot 5.
> 30-Sep 21:43 chet-sd JobId 584: Recycled volume "A0000005" on device  
> "Exabyte VXA-2 Drive" (/dev/rmt/0cbn), all previous data lost.
> 
> Thanks,
> Martijn

In addition to this this is the Device config in bacula-sd.conf

Device {
  Name = "Exabyte VXA-2 Drive"
  Drive Index = 0
  Media Type = "VXA-2"
  Device Type = Tape
  Archive Device = /dev/rmt/0cbn
  AutomaticMount = yes
  AlwaysOpen = yes
  RemovableMedia = yes
  RandomAccess = no
  AutoChanger = yes
  Changer Command = "/opt/csw/etc/bacula/mtx-changer %c %o %S %a %d"
  Alert Command = "sh -c '/opt/csw/sbin/tapeinfo -f %c |grep
TapeAlert|cat'"
  Changer Device = /dev/scsi/changer/c2t0d0
  Label Media = yes
  Offline On Unmount = no
  Hardware End of Medium = no
  BSF at EOM = yes
  Backward Space Record = no
  Fast Forward Space File = no
  Two EOF = yes
}


-------------------------------------------------------------------------
This SF.Net email is sponsored by the Moblin Your Move Developer's challenge
Build the coolest Linux based applications with Moblin SDK & win great prizes
Grand prize is a trip for two to an Open Source event anywhere in the world
http://moblin-contest.org/redirect.php?banner_id=100&url=/
_______________________________________________
Bacula-users mailing list
Bacula-users AT lists.sourceforge DOT net
https://lists.sourceforge.net/lists/listinfo/bacula-users

<Prev in Thread] Current Thread [Next in Thread>
  • Re: [Bacula-users] Bacula-users Digest, Vol 30, Issue 8, Martijn de Munnik <=