On Friday 28 July 2006 14:25, Alan Pearson wrote:
>I think I've run into another problem indirectly realted to my earlier
>issues.
>
>I've been trying in vein to get a Level 0 dump of the machine onto tape.
>
>I've told amanda to use SERVER compression, but unfortunatley, amanda
>planner seem to take the estimates from the client without compression
>when calculating what it can fit on tape.
>
>So in reality, if I go over the uncompressed size of the tape as defined
>in tape type, then this will never get to tape, even though it may fit on
>after compression.
>
>This is at the planner stage, so Amanda doesn't even dump the system to
>disk to see what size it really is.
>
>Anybody any idea how to get round this one ?
>
Time to make its history maybe. Amanda keeps track of the compression
achieved on a given DLE, and uses that historical figure to estimate the
new backup being contemplated. And without any history, probably assumes
a zero for compression effectiveness. Here, for relatively stable DLE's,
it can get very very accurate after a few weeks.
>Cheers,
--
Cheers, Gene
People having trouble with vz bouncing email to me should add the word
'online' between the 'verizon', and the dot which bypasses vz's
stupid bounce rules. I do use spamassassin too. :-)