Define it as drive 3, not drive 1. You have a syntax error.
Regards,
Linda Zgonce
IBM Global Services South
CORP Rick
Willmore To: ADSM-L AT VM.MARIST
DOT EDU
<[email protected] cc:
OM> Subject: Re: Element addresses
for new scsi LTO drive
Sent by: "ADSM:
Dist Stor
Manager"
<[email protected]
.EDU>
03/29/2004 12:43
PM
Please respond to
"ADSM: Dist Stor
Manager"
tsm: TSM>define drive autolib drive1 online=yes element=258
cleanfreq=asneeded
ANR8366E DEFINE DRIVE: Invalid value for ELEMENT parameter.
ANS8001I Return code 3.
Same error.
R.
-----Original Message-----
From: Linda Zgonce [mailto:lindazg AT US.IBM DOT COM]
Sent: Monday, March 29, 2004 6:16 AM
To: ADSM-L AT VM.MARIST DOT EDU
Subject: Re: Element addresses for new scsi LTO drive
You have a syntax error in your ITSM define drive command. Try this :
tsm: TSM>define drive autolib drive3 online=yes element=258
cleanfreq=asneeded
Regards,
Linda Zgonce
IBM Global Services South -ITSM
CORP Rick
Willmore To:
ADSM-L AT VM.MARIST DOT EDU
<[email protected] cc:
OM> Subject: Element addresses
for new scsi LTO drive
Sent by: "ADSM:
Dist Stor
Manager"
<[email protected]
.EDU>
03/26/2004 01:19
PM
Please respond to
"ADSM: Dist Stor
Manager"
Hey all,
I noticed that others of the list seem to have similar element address
problems but I didnt see my solution so I was hoping to throw this one out
and see what sticks.
I just added a new LTO (ver1) drive to our Scalar 100 Library. I used
lbtest and can see the element address reported by the new drive is 258
(the 2 previous drives are 256 and 257). When I try to move the media to
the 258 address or define the new drive to tsm I receive an error.
hal> lsdev -Cc tape
rmt0 Available 2A-09-00-3,0 LTO Ultrium Tape Drive
rmt1 Available 2A-09-00-4,0 LTO Ultrium Tape Drive
rmt2 Available 2A-09-00-2,0 LTO Ultrium Tape Drive <-- new drive
enter selection: 8
Library Element Count:
compcode = 0
number of drives = 3
number of storage slots = 42
number of transport elem = 1
number of entry exit ports = 12
analyze rc 0 err 0 (Successful,Error 0)
cc 0 (Successful) resid 0 data 0
Total elapsed time in seconds = 3.00
Library Inventory:
Drive 1 (address 256 EMPTY)
abnormal_state = 0, accessible = 1, scsi_bus_not_pres = 0,
scsi_bus_id_flag = 1, scsi_bus_id = 3, lun_flag = 0,
lun = 0, source_addr_flag = 0, source_elem_addr = 0,
invert_media_flag = 0, barcode_flag = 1, barcode_len = 36
Drive 2 (address 257 EMPTY)
abnormal_state = 0, accessible = 1, scsi_bus_not_pres = 0,
scsi_bus_id_flag = 1, scsi_bus_id = 4, lun_flag = 0,
lun = 0, source_addr_flag = 0, source_elem_addr = 0,
invert_media_flag = 0, barcode_flag = 1, barcode_len = 36
Drive 3 (address 258 EMPTY)
abnormal_state = 0, accessible = 1, scsi_bus_not_pres = 0,
scsi_bus_id_flag = 1, scsi_bus_id = 2, lun_flag = 0,
lun = 0, source_addr_flag = 0, source_elem_addr = 0,
invert_media_flag = 0, barcode_flag = 1, barcode_len = 36
enter selection: 11
transport element address: 1
source address moving from: 11
destination address moving to: 258
invert option: (1) invert (0) not invert:
execute move_medium taddr = 1 saddr = 11 daddr = 258 invert = 0
analyze rc -1 err 22 (EINVAL,Invalid argument)
cc 0 (Successful) resid 0 data 0
error_state last_status 22 (EINVAL) last_compcode 207 (DD_ILLEGAL_REQUEST)
information 0 number_sense 18
Sense KEY/ASC/ASCQ = 5/21/ 1
KEY meaning is illegal request
ASC/ASCQ meaning is invalid element address
sense bytes 000-015: 70 0 5 0 0 0 0 a 0 0 0 0 21 1 0 c0
sense bytes 016-031: 0 4
analyze return_error cc 207 (DD_ILLEGAL_REQUEST)
analyze conclusion ... ERROR not as expected
ERROR, test failed!
Total elapsed time in seconds = 7.00
Return to continue:
tsm: TSM>define drive autolib drive1 online=yes element=258
cleanfreq=asneeded
ANR8366E DEFINE DRIVE: Invalid value for ELEMENT parameter.
ANS8001I Return code 3.
Any help is appreciated.
Rick.
|