Re: 3590B1A -> 3590E1A - Repairing VCR data
1999-10-29 10:26:57
Richard,
I was one of the ones who had the problem, unfortunately I read the
readme for release 3.1.2.40 of adsm, an excerpt of that readme
follows.
Configurations:
Device Driver level: Atape.4.4.0.0
(ftp://index.storsys.ibm.com/devdrvr/AIX)
Microcode level:
3590E - EC F23200 D01C_502
I showed this to my CE when we were upgrading the drives and they
installed this level of microcode which produced the VCR error
problem.
Jim Sporer
______________________________ Reply Separator _________________________________
Subject: Re: 3590B1A -> 3590E1A - Repairing VCR data
Author: "ADSM: Dist Stor Manager" <ADSM-L AT VM.MARIST DOT EDU> at IPNET
Date: 10/29/99 7:45 AM
I'm curious as to how many sites had their IBM CEs spontaneously apply the
corrective C747 3590 microcode at 3590E install time, based upon existing and
previously installed drives vs. how many sites had to run into the problem and
then go looking for a solution?
Richard Sims, BU
|
<Prev in Thread] |
Current Thread |
[Next in Thread>
|
- 3590B1A -> 3590E1A - Repairing VCR data, Michel
- Re: 3590B1A -> 3590E1A - Repairing VCR data, ADSML
- Re: 3590B1A -> 3590E1A - Repairing VCR data, Richard Sims
- Re: 3590B1A -> 3590E1A - Repairing VCR data, Walter de Jong
- Re: 3590B1A -> 3590E1A - Repairing VCR data, Paul J Besz
- Re: 3590B1A -> 3590E1A - Repairing VCR data, James SPORER
- Re: 3590B1A -> 3590E1A - Repairing VCR data, Michel
- Re: 3590B1A -> 3590E1A - Repairing VCR data, Richard Sims
- Re: 3590B1A -> 3590E1A - Repairing VCR data,
James SPORER <=
- 3590B1A -> 3590E1A - Repairing VCR data, Michel
- Re: 3590B1A -> 3590E1A - Repairing VCR data, Walter de Jong [SMTP:walter
|
|
|