Re: [Veritas-bu] Getting Status 96 with 201 scratch tapes
2012-03-16 09:15:38
Just so I didn't leave this hanging out
there, I had 201 tapes with volume expirations that had expired. It
was a good lesson in the difference between data expiration and volume
expiration.
Thank you for all of the input!
From:
David McMullin <David.McMullin AT CBC-Companies DOT com>
To:
"veritas-bu AT mailman.eng.auburn DOT edu"
<veritas-bu AT mailman.eng.auburn DOT edu>
Date:
03/09/2012 01:12 PM
Subject:
Re: [Veritas-bu]
Getting Status 96 with 201 scratch tapes
Sent by:
veritas-bu-bounces AT mailman.eng.auburn DOT edu
What is the output of this command:
/usr/openv/volmgr/bin/vmpool -list_scratch
Is your defined scratch pool what you expected?
I run a cron job that verifies my available scratch tapes and sets my pool
several times a day, ever since I found there is a bug in the java gui
that can set a pool as scratch by mistake...
This command will set it for you: (my scratch pool is named scratch_pool)
/usr/openv/volmgr/bin/vmpool -set_scratch scratch_pool
------------------------------
Message: 6
Date: Fri, 9 Mar 2012 09:04:56 -0500
From: scott.george AT parker DOT com
Subject: [Veritas-bu] Getting Status 96 with 201 scratch tapes
To: 'Veritas' <veritas-bu AT mailman.eng.auburn DOT edu>
Message-ID:
<OFC07DD08A.E00282F7-ON852579BC.004CCACF-852579BC.004D895B AT parker DOT com>
Content-Type: text/plain; charset="us-ascii"
Here is my environment:
NBU 7.1.0.3 on an AIX 6.1 Master (also acting as media server in this
instance)
My scratch pool has 201 tapes inside the robot. Robot is STK SL8500
with
20 9840C Drives. I am using ACSLS.
Overnight vaults failed with the duplication jobs ending in error 96
(unable to allocate new media for backup, storage unit has none
available).
What gives?
"PLEASE NOTE: The preceding information may be confidential or
privileged. It only should be used or disseminated for the purpose
of conducting business with Parker. If you are not an intended
recipient, please notify the sender by replying to this message and
then delete the information from your system. Thank you for your
cooperation."
_______________________________________________
Veritas-bu maillist - Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
"PLEASE NOTE: The preceding information may be confidential or
privileged. It only should be used or disseminated for the purpose
of conducting business with Parker. If you are not an intended
recipient, please notify the sender by replying to this message and
then delete the information from your system. Thank you for your
cooperation."
_______________________________________________
Veritas-bu maillist - Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
|
|
|