Guys, thanks for all the help.
This is our Netbackup test server. So we decided
to reinstall Netbackup. After that now Netbackup do see the robot.
I do not know why? maybe it was a conflict some where along
the first time we configure and did not know it.
Anyway, in my case we reinstall Netbackup 5.1 and the problems solve.
I want to thanks everyone that tried to help me.
De-
-------------- Original message ----------------------
From: "Logan, Lee (N-BAE Systems)" <lee.logan AT lmco DOT com>
> De-
>
> I have 2 more suggestions based on your /var/adm/messages.
>
> Knowing you are on UNIX, open 2 windows. In one windows do a tail -f
> /var/adm/messages.
> In the other windows do your robtest and see if the errors are directly
> related to the robotest.
>
> 2nd suggestions is verify your robot configuration and check your scsi
> id's aren't conflicting. OK I lied I have 4 things.
>
> 3rd suggestion..... Does your OS see the robot with like a
> ok> probe-scsi-all
>
> Obviously this would require a power down to the boot prompt.
> 4) Does your robot show up in an sgscan (command located under
> /usr/openv/volmgr/bin)
>
> Regards,
>
> Lee Logan
> BAE Systems Information Technology
> 719-277-4772
> "Efforts and courage are not enough without purpose and direction."
>
>
> -----Original Message-----
> From: DeAnna_nguyen AT comcast DOT net [mailto:DeAnna_nguyen AT comcast DOT
> net]
> Sent: Wednesday, April 19, 2006 1:55 PM
> To: Logan, Lee (N-BAE Systems); Paul Keating;
> veritas-bu AT mailman.eng.auburn DOT edu
> Subject: RE: [Veritas-bu] Needs help to configure Netbackup 5.1 to see
> Sun L280 tape library
>
> Lee,
>
> I will do as your sugestions. I will replace cable first, then SCSI card
> after.
> I just want to see is it cable cause problem or card or none of the
> above.
>
> Anyway, thank you for your time.
>
> De-
> -------------- Original message ----------------------
> From: "Logan, Lee (N-BAE Systems)" <lee.logan AT lmco DOT com>
> > DeAnna,
> >
> > I had this problem here at my site off and on for awhile. While I
> > could see the robot through sya cfgadm -al, Netbackup was clueless.
> > For me it ended up being a problem with the fiber. In my case, the
> > Controller Card in the robot itself was flaky. I would double check
> > all of your connections and controllers.
> >
> > Just my 2 cents worth......
> >
> >
> > Lee Logan
> > BAE Systems Information Technology
> > 719-277-4772
> > "Efforts and courage are not enough without purpose and direction."
> >
> >
> > -----Original Message-----
> > From: veritas-bu-admin AT mailman.eng.auburn DOT edu
> > [mailto:veritas-bu-admin AT mailman.eng.auburn DOT edu] On Behalf Of
> > DeAnna_nguyen AT comcast DOT net
> > Sent: Wednesday, April 19, 2006 12:32 PM
> > To: Paul Keating; veritas-bu AT mailman.eng.auburn DOT edu
> > Subject: RE: [Veritas-bu] Needs help to configure Netbackup 5.1 to see
>
> > Sun L280 tape library
> >
> > Paul,
> >
> > L280 is connecting backup server.
> >
> > Thanks,
> >
> > De-
> > -------------- Original message ----------------------
> > From: "Paul Keating" <pkeating AT bank-banque-canada DOT ca>
> > > Is the robot connected to the netbackup server or to your NDMP host?
> > >
> > > Paul
> > >
> > > --
> > >
> > >
> > > > -----Original Message-----
> > > > From: veritas-bu-admin AT mailman.eng.auburn DOT edu
> > > > [mailto:veritas-bu-admin AT mailman.eng.auburn DOT edu] On Behalf Of
> > > > DeAnna_nguyen AT comcast DOT net
> > > > Sent: April 19, 2006 2:08 PM
> > > > To: veritas-bu AT mailman.eng.auburn DOT edu
> > > > Subject: [Veritas-bu] Needs help to configure Netbackup 5.1 to see
>
> > > > Sun L280 tape library
> > > >
> > > >
> > > > Hello Netbackup gurus,
> > > >
> > > > I am new with Netbackup, thus I need your help if you can.
> > > >
> > > > First:
> > > >
> > > > Server Sun ultra 60.
> > > > OS: Solaris 8 patch upto date.
> > > >
> > > > Veritas Software: Netbackup 5.1 MP3 + NDMP three ways backup.
> > > > I have only one server. Which is: Master + Media
> > > >
> > > > Here is what I don't know.
> > > >
> > > > I can run robtest and can move tape in and out drive, but can't
> > > > get netbackup to see a robot.
> > > >
> > > > Here is the error from the /var/adm/messages:
> > > >
> > > > "tsdd[10657]: [ID 100463 daemon.error] TSD(1) unavailable:
> > > > initialization failed: Unable to sense robotic device Apr 19
> > > > 07:42:49 netbackup tsdd[10859]: [ID 271271 daemon.error] TSD(1)
> > > > [10657] Mode_sense error Apr 19 07:42:49 netbackup tsdd[10859]:
> > > > [ID
> > > > 290852 daemon.error] TSD(1) key 5h, ASC 24h, ASCQ 0h, INVALID
> > > > FIELD IN CDB Apr 19 07:42:49 netbackup tsdd[10657]: [ID 100463
> > > > daemon.error] TSD(1) unavailable: initialization failed:
> > > > Unable to sense robotic device
> > > > Apr 19 07:44:51 netbackup tsdd[10868]: [ID 271271 daemon.error]
> > > > TSD(1) [10657] Mode_sense error Apr 19 07:44:51 netbackup
> > > > tsdd[10868]: [ID 290852 daemon.error] TSD(1) key 5h, ASC 24h, ASCQ
>
> > > > 0h, INVALID FIELD IN CDB Apr 19 07:44:51 netbackup tsdd[10657]:
> > > > [ID
> > > > 100463 daemon.error] TSD(1) unavailable: initialization failed:
> > > > Unable to sense robotic device
> > > > Apr 19 07:46:53 netbackup tsdd[10881]: [ID 271271 daemon.error]
> > > > TSD(1) [10657] Mode_sense error Apr 19 07:46:53 netbackup
> > > > tsdd[10881]: [ID 290852 daemon.error] TSD(1) key 5h, ASC 24h, ASCQ
>
> > > > 0h, INVALID FIELD IN CDB Apr 19 07:46:53 netbackup tsdd[10657]:
> > > > [ID
> > > > 100463 daemon.error] TSD(1) unavailable: initialization failed:
> > > > Unable to sense robotic device
> > > > Apr 19 07:47:50 netbackup tsdd[10657]: [ID 271271 daemon.error]
> > > > TSD(1) [10657] Mode_sense error Apr 19 07:47:50 netbackup
> > > > tsdd[10657]: [ID 290852 daemon.error] TSD(1) key 5h, ASC 24h, ASCQ
>
> > > > 0h, INVALID FIELD IN CDB "
> > > >
> > > > And I ran ./tpautoconf -report_disc
> > > >
> > > > ======================= Missing Device (Drive)
> > > > ======================= Drive Name = ndmpdr Drive Path =
> > > > /ndmp//dev/rmt/0cbn Inquiry = "-"
> > > > Serial Number =
> > > > TSD(1) definition Drive = 1
> > > > Hosts configured for this device:
> > > > Host = netbackup02
> > > > ======================= New Device (Tape) =======================
> > > > Inquiry = "QUANTUM DLT7000 2150"
> > > > Serial Number = CX917S3450
> > > > Drive Path = /dev/rmt/0cbn
> > > > Found as TSD(1), Drive = 1
> > > >
> > > > So can some one give me an advice how to get this work?
> > > >
> > > > Thanks,
> > > >
> > > > De-
> > > > _______________________________________________
> > > > Veritas-bu maillist - Veritas-bu AT mailman.eng.auburn DOT edu
> > > > http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
> > > >
> >
> >
> >
> >
> > _______________________________________________
> > Veritas-bu maillist - Veritas-bu AT mailman.eng.auburn DOT edu
> > http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
>
>
>
|