Add an extra zero to a couple values in the BP.INI file:

List_Files_Timeout
Clear_Archive_Bit_Incr_Wait

This has solved it for us.

RCA

--
Ryan C. Anderson
Unix Administrator
United Defense L.P.
desk   763.572.6684
pager 952.235.9936
mobile 612.419.9362

>>> <JLaurie AT csu DOT org> 09/03/02 10:04AM >>>
Just recently I've begun testing non-target NetWare backups. Last
Sunday, 
I got successful full backups of a NetWare server (both NetWare File 
System & Novell Directory). This weekend, however, the backup failed
with 
an error Status Code: 71. Checking the error logs I also noticed that I

got a "unable to connect to service, scheduled access not specified" 
message. I checked the Troubleshooting Guide and found that the
additional 
error could be expected when using the target'd backup. As noted above
I'm 
doing non-target'd backups and I ensured that, indeed, the class type
was 
"NetWare" and the files list contained only a slash (/).
Does anyone have experience with NetWare backups? Is there anything I'm

missing? I'm starting to look bad in the eyes of the NetWare group...I

promised that I could improve backup performance and increase
reliability 
vs ArcServe.