Paul,
In answer to question 3
In your /kernel/drv/st.conf, you need the following selected;

     "QUANTUM DLT7000",      "Quantum DLT7000", "DLT7k-data",
and
     DLT7k-data =    1,0x38,0,0x1D639,4,0x82,0x83,0x84,0x85,2;
Regards,
Mark